8 Technical data
TZ-67
Throw length
Max. static
Effective
Throw
length
TD523351_1
A
B
C
D
E
TD523321
Inlet pressure
A: m
B: ft
C: nozzle sizes
D: psi
E: bar
Note: Throw lengths are measured as horizontal throw length at static condition. Vertical throw length upwards is approx. 1/3
less. Effective throw length is defined as impact centre of jet 250 mm water column (50 lbs/sq.ft). Effective throw length varies
depending on jet transverse speed over surface, substance to be removed, cleaning procedure and agent. The inlet pressure
has been taken immediately before the machine inlet. In order to achieve the performance indicated in the curves, the pressure
drop in the supply lines between pump and machine must be taken into consideration.
36