26
7. Maintenance
7.2 Assembly of
Think
Top
®
Step 1
Place sensor unit in base and tighten screw (torque: 1 Nm).
Step 2
Assemble base with adapter by turning adapter slightly
anticlockwise and tighten the three screws (1.9 Nm).
Note:
Turn banjo
connection!
Step 3
1. Replace solenoid valves (up to three) with new ones.
2. Tighten screws (0.2 Nm).
Step 4
Replace cover of
Think
Top
®
and tighten the three screws
(0.6 Nm).
Study the instructions carefully.
Handle scrap correctly.
Always keep spare X-rings in stock.
Summary of Contents for ThinkTop Digital 8
Page 1: ...IM70824 GB6 2002 12 ThinkTop Digital 8 30 VDC PNP NPN Instruction Manual...
Page 3: ...4...
Page 28: ...29...