9.2 Appendix B – Setup with Terminal Interface
9.2.2 Load cell signals
To get the main menu press “Enter” one or more times until the main menu is displayed:
--------------------------------------------------
--- MAIN MENU
(1) show Info
(2) change Settings
(3) reset and switch to Download mode
(4) show LC signals
--------------------------------------------------
Then press “4” to start showing the load cell signals like this:
--------------------------------------------------
--- LC signals:
0000,
-22868;0000,
-23281;0000,
-24449;0000,
-8216
0000,
-22871;0000,
-23277;0000,
-24448;0000,
-8215
0000,
-22868;0000,
-23279;0000,
-24450;0000,
-8216
0000,
-22871;0000,
-23280;0000,
-24451;0000,
-8215
0000,
-22864;0000,
-23280;0000,
-24448;0000,
-8215
Each line will contain the load cell status followed by the load cell signal for each load cell. These line
will be shown continuously until stopped. To stop display of load cell signals press “4”, “Enter” or “Esc”
in order to return to the
Main Menu
looking like this:
--------------------------------------------------