background image

 

 

Page 16 

 

 

Instruction Manual, Alfa Laval Level Switch 

TE91K023-EN5 

 

8.  Troubleshooting

 

 

No electrical output from the sensor 

In case of no electrical signal from the sensor please follow this checklist for identifying the problem. 



Loosen and remove the cover 



Measure if there is 10-35 VDC on the two supply terminals to make sure that there is power to the sensor 



Check if wiring is according to the scedule on p. 12 

 

If all of these points is checked, and the sensor still have an error, the level switch needs to be returned to Alfa Laval for 
repair. 

 

8.1 Troubleshooting 

Summary of Contents for TE67O

Page 1: ...TE91K023 EN5 ESE01748EN Date of issue October 2019 First published 2010 Instruction Manual Alfa Laval Level Switch TE67O...

Page 2: ...specifications 7 4 1 Technical specifications 7 5 Installation 9 5 1 Mechanical installation 9 5 2 General installation guidelines 11 5 3 Electrical installation M12 plug 12 5 4 Electrical installati...

Page 3: ...echnical file is the signer of this document This Declaration of Conformity replaces Declaration of Conformity dated 2019 02 01 1 EC Declaration of Conformity Alfa Laval Kolding A S Company name Albue...

Page 4: ...llowed to avoid damage to the level switch NOTE Indicates important information to simplify or clarify procedures Unsafe practices and other important information are emphasized in this manual Warning...

Page 5: ...rams Before switching off the supply voltage check the possible effects on other equipment and the processing system Ensure that the supply voltage and the conditions in the environment comply with th...

Page 6: ...necting the electronics please see page 12 The Alfa Laval level switch TE67O is default configured to cover the major part of potential applications Where custom er specific configuration is required...

Page 7: ...parts material PEEK Natura AISI 316L 1 4404 AISI 304 1 4301 optional Surface roughness wetted parts Ra 0 8 m Process conditions Process temperature Refer to table page 8 Process pressure Refer to tabl...

Page 8: ...EU directives EN61000 6 2 EN61000 6 3 PED 2014 68 EU EN10 2011 1935 2004 2023 2006 FDA FDA 21CFR177 2415 Approvals Hygienic 3 A Standard 74 07 on some models see Chapter 9 Safety cULus Listed Class 2...

Page 9: ...g adaptor For the TE67O0Dx1111xx to be compliant to 3 A it must be installed in the welding adaptor TE67N000000019 The TE67N000000019 welding adaptor can be fitted on tanks and on pipes O ring TE67N00...

Page 10: ...nstallation comply to 3 A regulations which means that Only 3 A approved welding adaptor is to be used TE67N000000019 The inspection hole should be visible and drained Mount the adapter in a self drai...

Page 11: ...angle of 5 which makes it self draining When installed in the bottom of tanks it is recommended to use the CFF process connection TE67N000000019 or the Unique Flexbody connection to get a flush mount...

Page 12: ...own Supply 2 White Teach in 3 Blue Supply 4 Black Output PNP M12 4 pin connection 5 4 Electrical installation with M16 cable gland 5 Installation Warning Note Check the maximum temperature for the cab...

Page 13: ...powdery or in other ways leaving parts of the media at the sensor tip this situation has to be established also during the Teach In process Otherwise a faulty calibration can be the result If Teach In...

Page 14: ...K AISI 316 L 15 PEEK AISI 316 L 10 100 13 Safety M16 M12 56 58 A F 22 G 1 2 A 12 44 PEEK AISI 316L Clamp front flushable CFF TE67O0Dx1110xx G TE67O04x1110xx 55 mm housing TE67Oxxxxxxxxx G 100 mm slidi...

Page 15: ...ings 4 4 34 6 5 34 5 6 34 64 34 34 50 5 Clamp DN 38 ISO2852 Clamp DN 40 DIN32676 TE67O02x1110xx Clamp DN 51 ISO2852 Clamp DN 50 DIN32676 TE67O03x1110xx DN 25 DIN11851 TE67OxAxxxxxxx DN 40 DIN11851 TE6...

Page 16: ...this checklist for identifying the problem Loosen and remove the cover Measure if there is 10 35 VDC on the two supply terminals to make sure that there is power to the sensor Check if wiring is acco...

Page 17: ...11851 TE67OxCxxxxxxx Clamp front flushable CFF TE67OxDxxxxxxx G 100 mm sliding TE67OxExxxxxxx G 250 mm sliding TE67OxFxxxxxxx Unique Flexbody type F DN 25 1 TE67OxMxxxxxxx Unique Flexbody type N DN 40...

Page 18: ...X X TE67OxExxxxxx2 G 100 mm sliding X TE67OxFxxxxxx2 G 250 mm sliding X TE67OxAxxxxxx2 DN 25 DIN11851 X TE67OxBxxxxxx2 DN 40 DIN11851 X TE67OxDxxxxxx2 DN 50 DIN11851 X TE67O0Dx1110xx Clamp front flush...

Page 19: ...Laval office Be sure to follow the instructions closely 10 1 Service Repair 10 2 Warranty The warranty conditions are subject to the legal warranty period of 12 months from the date of delivery In ca...

Page 20: ...Page 20 Instruction Manual Alfa Laval Level Switch TE91K023 EN5...

Page 21: ...sponsibility of the user of this document to comply with all applicable intellectual property laws Without limiting any rights related to this document no part of this document may be copied reproduce...

Reviews: