3 Installation
Study the instructions carefully and pay special attention to the warnings!
The direction of rotation of the impeller can be checked by observing the direction of rotation of the motor fan.
- See the indication label on the pump.
3.3
Installation/Pre-use check - MR-185S and MR-200S
Step 1
Always read the technical data carefully.
Never stick your fingers or any tool through the adaptor or the
drain hole in the pump casing when the pump is running.
Always have the pump electrically connected by
authorised personnel.
CAUTION
Alfa Laval cannot be held responsible for incorrect
installation.
Step 2
Ensure a clearance of at least 0.5 m around the pump.
3100-0013
Step 3
Ensure that the flow direction is correct.
3100-0014
Step 4
1. Ensure that pipelines are routed correctly.
2. Ensure that connections are tight.
Min. 1m
Few bends!
Correct!
3100-0015
Remember seal rings!
10