5 Maintenance
Read the instructions carefully. The items refer to the parts list and service kits section.
Lubricate the rubber seals before fitting them.
: Relates to the shaft seal.
Step 5
1. Fit impeller (27) on stub shaft (7).
2. Ensure that the clearance between the impeller and back plate
(25) is correct: 0.5 mm (0.02 inch) for LKH-5.
LKH-5 = 0.5 mm
(0.02 inch)
Step 6
Tighten screws (4) evenly to 15 Nm (11 lbf-ft).
34
Summary of Contents for LKH
Page 1: ...3000 0059 ESE00698 EN21 2017 05 Original manual Instruction Manual LKH Centrifugal Pump...
Page 2: ......
Page 45: ...45...
Page 54: ...54...