5 Maintenance
5.2 Cleaning Procedure
C
Clleeaanniinngg P
Prroocceedduurree ffoorr S
Sooiilleedd IIm
mppeelllleerr S
Sccrreew
w TTaappppeedd H
Hoollee::
1. Remove stub shaft (7) per section 4 of Service manual.
2. Submerge and soak Stub Shaft for 5 minutes in COP tank with 2% caustic wash
3. Scrub the blind tapped impeller screw hole vigorously by plunging a clean 1/2” diameter sanitary bristle pipe brush in and out
of the hole for two minutes while submerged.
4. Soak Stub Shaft (7) in acid sanitizer for 5 minutes, then scrub blind tapped hole as described in step 3 above.
5. Rinse well with clean water and blow-dry blind tapped hole with clean air.
6. Swab test the inside of the tapped hole to determine cleanliness.
7. Should the swab test fail, repeat steps 2 thru 6 above until swab test is passed.
Should swab testing continue to fail, or time is of the essence, install a new (spare) Stub Shaft (7).
18
CONTACT CSI FOR MORE INFORMATION | CSIDESIGNS.COM | [email protected] | 417.831.1411