3 Installation
Study the instructions carefully.
The valve is supplied as separate parts to facilitate welding.
Check the valve for smooth operation after welding.
3.3
Welding
Step 1
To ensure safe operation and easy maintenance of the valve, be
sure to follow the recommended installation dimensions in the
table below.
Valve size
A (mm)*
B (mm)*
C (mm)*
51 mm / 2”
596
603
644
63.5 mm / 2½”
604
609
652
76 mm / 3”
611
643
659
* Recommended clearance for ThinkTop
®
included.
2321-0063
C
A
B
Step 2
Assemble the valve.
Pay special attention to the warnings!
2321-0064
!
13