6/20
ALFA IN a.s.
©
www.alfain.eu
ELECTROMAGNETIC COMPATIBILITY
The welding device is in terms of interference designed primarily for industrial
areas. It meets the requirements of EN 60974-10 class A and it isn’t designed
for using in residential areas, where the electrical energy is supplied by public
low-voltage power supply network. It can be here potential problems with
ensuring of electromagnetic compatibility in this areas, due to interference
caused by power lines as well as the radiated interference.
During operation, the device may be the source of interference.
Caution
We warn users
, that they are responsible for possible interference from
welding.
3. TECHNICAL DATA
Method
MMA - AC MMA - DC TIG - AC
TIG - DC
Mains voltage
V/Hz
3x400/50-60
Welding current range
A
30 - 300
5 - 350
30 - 350
5 - 350
Open-circuit voltage U
20
V
78,0
81,0
78,0
77,0
Mains protection
A
25 @
Max. effective current I
1eff
A
21,6
16,9
Welding current (DC=100%) I
2
A
270
270
280
280
Welding current (DC=60%) I
2
A
300
330
340
340
Welding current (DC=x%) I
2
A
60%=300
45%=350
50%=350
50%=350
Protection
IP23S
Standards
EN 60 974-1, EN 60 974-10 cl.A
Dimensions (w x l x h)
mm
492 x 891 x 873
Weight
kg
88,0
Cooling power (Q=1l/min)
kW
---
0,74
Total liquid content
l
---
4,0
Max. pressure
Bar
---
3,5
Max. flow
l/min
---
8,0
Caution
Due to the size of installed power can be for connecting device to
public distribution network necessary the agreement from distribution
establishment.