Confidential
Alesis Service Manual
8-31-0103-A
Verify
that the lens is free of scratches, and that the LEDs have a
consistent and clear appearance.
Problems
with no response to Band Button 2 indicate Band Button 2 has
mechanical fit problem and the test has FAILED. Problems with LED
inspection indicate test has FAILED.
Failure
of this inspection indicate that the DUT cannot continue further
testing.
6)
Press
Band Button 3
. This button is located on the far left hand side of the unit,
underneath the column marked “40”. This button runs the software revision
check.
Verify
that the seven-segment display changes.
Verify
that the seven-segment display shows the current software revision
number.
Problems
with incorrect software revision number indicate that the
incorrect software is being loaded into the DUT, and the test has FAILED.
Problems
with no response to Band Button 3 indicate Band Button 3 has
mechanical fit problem and the test has FAILED.
Failure
of this inspection indicate a serious problem with current
firmware for production. The DUT cannot continue further testing, and
the Alesis Engineers listed at the top of this document should be asked for
current software or current version of this document before continuing
production.
7)
In order, press
Band Button 4
through
Band Button 60.
Verify
that when the button is held, that the column above the
button lights, that the number corresponding to the button is shown in the
seven-segment display, and that the LED pattern is in working order as in
the Front Panel Sub Assembly Test.
Verify
that the lens is free of scratches, and that the LEDs have a
consistent and clear appearance.
Problems
with no response or flickering LEDs indicates poor or failed
mechanical fit for the switch, and the test has FAILED. If there seems to
be a problem with the numbers displayed in the seven-segment display,
then the display has also FAILED.
Failure
of this inspection indicate that the DUT cannot continue further
testing.
Summary of Contents for DEQ230
Page 9: ...WIRING DIAGRAM US EU UK AUS NZ D SERVICE DEQ 230 DOC...
Page 10: ...Packing Diagram US EU AK AUS NZ...
Page 11: ...D SERVICE DEQ 230 DOC Exploded View US AU UK AUS NZ...
Page 28: ...ME2FP208a sch 1 Tue Sep 17 13 07 36 2002...
Page 29: ...ME2FP208a sch 2 Tue Sep 17 13 07 47 2002...
Page 30: ...ME2FP208a sch 3 Tue Sep 17 13 07 56 2002...
Page 31: ...ME2FP208a sch 4 Tue Sep 17 13 08 05 2002...
Page 32: ...ME2FP208a sch 5 Tue Sep 17 13 08 20 2002...
Page 33: ...ME2FP208a sch 6 Tue Sep 17 13 08 28 2002...
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......