AlertLabs SENTREE Installation Manual Download Page 14

9

Secure temperature sensors

Tightly secure the liquid line (  / red) and vapor line (  / blue)  temperature sensors on the harness to their respective 

pipelines using the included cable ties, then wrap with foam tape. Attach the ambient (  / black) temperature sensor 
to a shaded location near the A/C unit, suspended in free air and out of direct sunlight.

Summary of Contents for SENTREE

Page 1: ...i SENTREE Installation Manual ALF 000008...

Page 2: ......

Page 3: ...SENTREE Installation Manual...

Page 4: ...60 Hz Maximum power consumption 12W REPLACEABLE FUSE Fuse specifications UL Listed Supplemental Circuit Protection T 5 0 A H 600 VAC Replace with same type and fuse rating Example Bel Fuse Inc 0ADKC5...

Page 5: ...o condenser units powered by 240 VAC single phase 60 Hz power and must use the 1 4 inch tabs on the line side of the condenser s contactor This Sentree device is intended for use on systems up to 600...

Page 6: ...1 2 3 4...

Page 7: ...d 1 Sentree main housing 2 Cable harness 3 Current sensor 4 Power supply fuse assembly 5 Pressure sensors 2 6 Installation manual 7 Cable bushing 8 Iso propyl alcohol wipe 9 Foam tape 3 10 Cable ties...

Page 8: ...Installation...

Page 9: ...1 Turn off the Power Switch the power to the air conditioner to the OFF position WARNING RISK OF ELECTRIC SHOCK CAN CAUSE INJURY OR DEATH DISCONNECT ALL REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICIN...

Page 10: ...e pressure sensors onto the service ports Make sure the connectors on top of the sensors are horizontal to prevent water from collecting inside the sensor Replace the caps onto the servicing end of th...

Page 11: ...he surface inside the electrical compartment Peel the adhesive pad on the power supply and attach it to the clean surface Clip the current sensor around either of the L1 or L2 mains cables from the ho...

Page 12: ...harness into the electrical compartment Plug the power supply and current sensor into the connectors on the harness Attach the green ground clip from the harness to an exposed sheet metal edge in the...

Page 13: ...pressure sensors Connect the red cable on the harness to the liquid line pressure sensor Connect the blue cable on the harness to the vapor line pressure sensor Arrange both pressure sensor cables in...

Page 14: ...vapor line blue temperature sensors on the harness to their respective pipelines using the included cable ties then wrap with foam tape Attach the ambient black temperature sensor to a shaded locatio...

Page 15: ...10 7 Mount the harness Attach the harness overmold to a secure location outside of the A C unit such as the A C support bracket or the vapor line A cable tie is provided...

Page 16: ...unit Plug the primary cable from the harness into the Sentree main housing by pressing the connector in and twisting Mount the Sentree main housing to a secure vertical surface with appopriate screws...

Page 17: ...d switch the power back to the ON position The indicator light on Sentree will flash red Monitor the light until it turns green up to 2 minutes indicating a good cellular signal has been achieved Sign...

Page 18: ...Need help For additional help or in case of issue visit alertlabs com support or contact us at help alertlabs com...

Page 19: ......