In The Box

A.

B.

C.

D.

E.

F.

 1x P168 Plesio Pager

 1x P176 Companion Mini (Monitor) + 2x Spare AAA (LR03) Batteries
 1x P153 Pager Power Supply

 2x Cable ties & Velcro Pads

 1x USB Stick containing;

-Quick start video, programming software & Instructions

 1x USB 2.0 Type-A to micro-USB cable

Page | 4

Summary of Contents for Companion Mini

Page 1: ...Wireless Epilepsy Support mini...

Page 2: ...on of seizures and the safeguard of individuals Please read this quick start guide carefully to ensure the correct set up use and maintenance of your new product for years to come If you have any ques...

Page 3: ...the Pager 6 Positioning and Setup 7 System Operation 8 Alarm Mode 8 Pager Charging 10 Pairing Instructions 10 Pairing the Monitor to the Pager 10 Maintenance Instructions 11 Routine Testing 11 How to...

Page 4: ...ypes Tonic clonic Partial Generalised The carer is then alerted via the Alert iT Safelink Radio System This offers a failsafe detection of radio integrity using a Class 2 radio receiver The carer must...

Page 5: ...Pager 1x P176 Companion Mini Monitor 2x Spare AAA LR03 Batteries 1x P153 Pager Power Supply 2x Cable ties Velcro Pads 1x USB Stick containing Quick start video programming software Instructions 1x USB...

Page 6: ...is woken up and placed into a test mode by pressing the recessed test button on the front of the monitor Figure 1 typically using a pen tip The internal red light will flash to indicate the unit is n...

Page 7: ...nd all three LEDs will flash The green Pager LED will blip every 8 seconds to show that the pager is awake and listening for alarm signals If the monitor is turned on you now see the red Monitor LED o...

Page 8: ...Companion Mini detects movement If you are happy that the monitor is picking up each press tap of the mattress then you can secure it into positon using the supplied Velcro pads or cable ties To use t...

Page 9: ...le using the provided software contact Alert it for support Alarm Mode When prolonged movements are detected the Alarm LED on the pager will light up it will make an audible alarm and will vibrate Pre...

Page 10: ...ff No Three Beeps 3 Flashes 3 Flashes 3 Flashes Switching On No Once Flash Once Flash Once Flash Once Pager battery getting low No No Flash every Second N A N A Pager battery getting very low No Sound...

Page 11: ...he Pager Ensure the monitor is turned on Pairing is only possible within 30 seconds of powering up the pager To pair the Monitor to the Page place the monitor close to the pager and press and hold the...

Page 12: ...compressed until dripping stops with a mild detergent 0 5 washing up liquid solution or by using an alcohol or baby wipe Avoid getting any liquid into the micro USB connector Changing Battery s in th...

Page 13: ...line for the purpos es of fault diagnosis and the provision of advice Repair or if this is not possible replacement of faulty equipment free of charge however the equipment must be returned to Alert i...

Page 14: ...x AAA LR03 Non rechargeable Battery Life 12 months Operating Temp 5 35 C Humidity 90 max Non condensing Sealing IP53 not waterproof The system complies with 93 42 EEC as a Class 1 Medical Device for u...

Page 15: ...onduct a risk assessment to determine if the level of reliability offered by the monitor is sufficient or if additional monitoring is needed Contact the manufac turer for assistance with Risk Evaluati...

Page 16: ...Atherstone House Desford Leicester LE9 9FE 01530 239 900 www alert it co uk www facebook com AlertitCareAlarms or join our supportive Epilepsy Forum UQ1386A Companion mini Quickstart doc v4 1...