Pure Air For Life

AIR PURIFIER SAFETY 

This manual provides important safety messages regarding your electrical home appliance. 

Always read, follow, and, save all safety directions.

Location Requirements

• 

Use a level surface at least 6” (15.2cm) from heat sources such as ranges, dryers, or heaters.

• 

Do not block air vent openings or place air purifier on a soft surface such as a bed or sofa.

• 

Never insert fingers or foreign objects into air grills or vents.

• 

Operate indoors only.

Electrical and Safety Requirements

 — Reduce your risk of fire or electrical shock. Failure 

to follow these instructions can result in death, fire or electrical shock.

• 

Do not connect unit to any electrical socket that is damaged.

• 

Ensure filter is correctly installed before turning on unit. Do not run the unit without a filter

• 

Always turn off the air purifier before unplugging.

• 

Do not use next to a source of heat, such as a range, heater or dryer.

• 

Do not use near a bath, shower, swimming pool or where a unit can get wet.

• 

Do not plug the air purifier into an outlet controlled by a dimmer switch.

• 

Do not use in a window.

• 

Unplug air purifier before servicing.

• 

Do not use an adapter. Do not use an extension cord.

• 

Always unplug the unit before changing the filter.

• 

Do not cover the unit or impede air flow.

• 

Change your filter at the recommended interval, so excess dust and particles do not build up.

• 

Do not exceed the rating of the power outlet or connection device. May cause electric shock 
or fire due to excess heat generation.

• 

Do not insert or pull out plug with wet hands, it may cause electric shock.

• 

Never try to take apart or repair the unit by yourself.

• 

Disconnect the power if strange sounds, smell or smoke comes from it. 

• 

Do not try to change the filter during operation.

• 

Do not drop the unit, as this can result in damage.

• 

Do not place heavy objects on the power cord and take care so that the cord is not com-
pressed as there is danger of fire or electric shock.

• 

Do not climb up or sit on the unit. You may be injured if you fall or if the unit falls over.

• 

Do not spray insecticides or any other flammable sprays near the machine. It may cause 
explosion or fire.

• 

Use only in the proper electrical socket type. Socket type (voltage & hertz) can be found 
on the product sticker on the side or bottom of the unit. Plugging the unit in to the incorrect 
socket type can damage/destroy the unit.

• 

WARNING! To reduce the risk of electric shock, this equipment has a grounding type plug 
that has a third (grounding) pin. This plug will only fit into a grounding type power outlet. If the 
plug does not fit into the outlet, contact qualified personnel to install the proper outlet. Do not 
alter the plug in any way.

Summary of Contents for BreatheSmart 40

Page 1: ...USER MANUAL Alen BreatheSmart 40 45i HEPA Air Purifier We would love to hear from you If you have any questions please contact us at 1 800 630 2396 ...

Page 2: ... Care Maintenance Replacing The Filter Why You Should Replace Your Filter Alen s AutoShip Filter Plans How To Replace The Filter Troubleshooting Tips Lifetime Limited Warranty 4 5 8 8 11 12 The 8 hr TWA Ozone for this product is 0 001 ppmv when tested in a 30 m3 chamber Refer to safety instructions in manual for more information ...

Page 3: ... not cover the unit or impede air flow Change your filter at the recommended interval so excess dust and particles do not build up Do not exceed the rating of the power outlet or connection device May cause electric shock or fire due to excess heat generation Do not insert or pull out plug with wet hands it may cause electric shock Never try to take apart or repair the unit by yourself Disconnect ...

Page 4: ...ve the FILTER button Green Yellow and Red The Green light will be illuminated for most of the life of the filter The Yellow light will come on shortly before your filter should be replaced This is the ideal time to order a new filter The Red light will be illuminated when it is time to replace the filter 6 After changing the filter hold the FILTER button down for five seconds This will reset the R...

Page 5: ...peeds Lights will display selected speed Child lock hold for 3 seconds to Lock Unlock the control panel Purified air output grill Rating label Control panel Side air intake Bottom air intake Handle for easy carrying Notifies you when it s time to replace the filter Touch for 5 seconds after changing filter to reset to green Touch to START or STOP your air purifier ...

Page 6: ...Lights will display selected speed Child lock hold for 3 seconds to Lock Unlock the control panel Purified air output grill Rating label Control panel Side air intake Bottom air intake Handle for easy carrying Notifies you when it s time to replace the filter Touch for 5 seconds after changing filter to reset to green Touch to START or STOP your air purifier Automatic Mode sets speed for optimal p...

Page 7: ...the Power Button a second time to turn the unit off completely Replacing The Filter The Filter Indicator has three lights Green Yellow and Red The Green light will be illuminated for most of the life of the filter Yellow light will come on shortly before your filter should be re placed This is the ideal time to order a new filter You may order a new filter at www alen com filters or by calling 1 8...

Page 8: ...ers will maintain the level of air quality you require Excessively dirty filters can compromise the level of clean air your air purifier can provide Alen s AutoShip Filter Plan Convenience Pure Air and Savings Regular replacement of your filter will extend the life of your air purifier and keep your air pure Alen filters provide efficient filtration for 6 months of heavy usage and 9 months of mode...

Page 9: ...sed filter by pulling out on the pull strings Place the used filter in a plastic bag to pre vent dust from re entering the air 4 Take the new filter out of the plastic bag and insert it into the air cleaner with the tab facing outward 5 Insert the bottom hooks on the front cover first and then the upper part of the cover will snap into place 1 To remove cover pull firmly on the cover near the top ...

Page 10: ...ld on with Velcro like strips This Pre Filter can be vacuumed or once removed washed to maintain efficient operation of the unit No other layers or parts of the filter can be washed cleaned or otherwise reused Please replace the filter regularly to maintain optimal performance I have an issue not listed in this manual Please visit www alen com and send us a message or call 1 800 630 2396 during bu...

Page 11: ...ossession of the original purchaser Proof of purchase must be presented to Alen s warranty service representative To help us validate your warranty we encourage you to register your Alen Air Purifier at www alencorp com register To obtain warranty service complete our online form or call 1 800 630 2396 The defective product or part must be shipped or delivered to Alen s authorized service center A...

Page 12: ...DING SENTENCE ALEN SHALL HAVE NO LIABILITY WHETHER UNDER A CAUSE OF ACTION IN TORT STRICT LIABILITY CONTRACT OR OTHERWISE TO ANY PERSON FOR ANY CLAIM INJURY LOSS DAMAGE OR EXPENSE INCLUDING ANY DIRECT INDIRECT SPECIAL CONSEQUENTIAL INCIDENTAL PUNITIVE OR EXEMPLARY DAMAGES IN ANY WAY ARISING OUT OF OR RELATING TO THE AIR PURIFIER OR ITS USE BY ANY PERSON SOME STATES DO NOT ALLOW LIMITATIONS ON AN I...

Page 13: ...Copyright 2018 Alen Corp All Rights Reserved BreatheSmart 40 45i pm May 31 2018 ...

Reviews: