Warnings & Safety Issues

 

   WARNING

lt is the responsibility of the user to operate the pump in conformance with OSHA rules for dispensing liquids. Pump containers 

should be grounded when using with flammable liquids to avoid static electricity. Pump should  be washed  

out before usage since processing lubricants could contaminate the fluid.
1     When using a hand pump (especially when pumping flammable, combustible or hazardous liquids) follow all electrical and 

safety codes, as well as the OH&S standards. 

2     Know the pump application, limitations, and potential hazards. The “WARNING” statements indicate potentially hazardous 

conditions for the operator or equipment. TAKE NECESSARY STEPS TO PROTECT PERSONNEL AND EQUIPMENT. Pump 

should only be used with liquids compatible with pump component materials. Consult PUMP CHEMICAL COMPATIBILITY 

CHART and PUMP SPECIFICATIONS. Also, the chemical supplier should be consulted regarding any questions of chemical 

compatibility, proper and safe use, and handling of chemicals. Misapplication of pump or use of incompatible liquids will  

void warranty.

 

   WARNING

In order to properly use this product familiarise yourself with this pump and also with the liquid (chemical, etc.) that is going to 

be pumped through the unit. Although this pump is suitable for many liquids, it is not suitable for all liquids!

3     Pumping hazardous, flammable, or combustible liquids, should only be done in buildings, rooms, or areas suited for this 

purpose. 

 

   WARNING

When filling cans, drums, etc. with combustible or flammable liquids, both container pumping from and container pumping to, 

should be bonded and grounded to dissipate possible accumulations of static electricity, and minimise sparks caused by static 

electricity. 

 

   WARNING

Removal of outer garments in work areas where there may be flammable or explosive liquids, which are ignitable with low 

electrical energy, can be fatal and/or cause property damage.

4     The “WARNING” and instructions for gasoline below pertain not only to gasoline, but to any flammable, combustible or 

hazardous fluid.

 

   WARNING

Gasoline is a highly flammable fuel. The improper use, handling, or storage of gasoline can be dangerous. Prevent accidents by 

following these safety rules:

 

a. Use gasoline only as fuel, never as a cleaning fluid.

 

b.  Use only an approved container to hold or store gasoline. Never store gasoline in familiar containers such as milk 

containers or soda pop bottles.

 

c. Store gasoline in a cool location, out of the reach of children. Never store gasoline near heat or an open flame.

 

d.  Provide a fire extinguisher nearby when working with gasoline. Be sure extinguisher is in operating condition - check 

the pressure gauge or indicator. Be familiar with its proper use. Consult local fire department for the correct type of 

extinguisher for your application. Extinguishers rated ABC by the National Fire Protection Association are appropriate 

for most applications.

 

e.  Provide positive shut-off valves on all permanent fuel supplies. Fuel lines must be of steel piping, adequately 

secured, and free from leaks.

 

f . Provide adequate ventilation, and clean up any spills when handling or pumping flammable liquids.

 

g. POSITIVELY NO SMOKING!

5     The “WARNING” and instructions for gasoline below pertain not only to gasoline, but to any flammable, combustible or 

hazardous fluid.

6     Secure the discharge line before starting the pump. An unsecured discharge line will slip, possibly causing personal injury 

and/or property damage.

7     Do not overtighten threaded fittings. One full turn past hand tight is usually enough to prevent leakage. Teflon ~ sealant tape 

is provided and should be used on all threaded joints, including the spout.

8     Check hoses for weak or worn condition before each use, making certain that all connections are secure.
9     Periodically inspect pump and system components. Perform routine maintenance as required.
10  Drain all liquids from the system before servicing.

 

   WARNING

Any pump used to transfer flammable liquids must be stored in a well ventilated area after use.

Visit our website at  

www.alemlube.com.au

 or 

www.alemlube.co.nz

2

NSW
TEL: (02) 9939 0711
FAX: (02) 9939 0411

QLD/PNG
TEL: (07) 3204 9166
FAX: (07) 3204 1224

VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266

WA
TEL: (08) 9209 3066
FAX: (08) 9209 3933

SA/NT
TEL: (08) 8241 7111
FAX: (08) 8241 7011

NZ
TEL: (09) 447 1007
FAX: (09) 447 1008

Summary of Contents for 801A

Page 1: ...semble to crank arm using the hex nut supplied Attach entire crank arm subassembly including handle handle shaft and hex nut onto pump shaft taking care to align setscrew to indent in rotor shaft 4 Thread suction tube into pump inlet Thread suction tube into suction tube Thread tail pipe onto suction tube section Use Teflon tape provided or equivalent sealant tape to seal suction tube threaded con...

Page 2: ... Gasoline is a highly flammable fuel The improper use handling or storage of gasoline can be dangerous Prevent accidents by following these safety rules a Use gasoline only as fuel never as a cleaning fluid b Use only an approved container to hold or store gasoline Never store gasoline in familiar containers such as milk containers or soda pop bottles c Store gasoline in a cool location out of the...

Page 3: ...ed other than as stated in the LIMITED WARRANTY above is made or authorized by Dayton PRODUCT SUITABILITY Many jurisdictions have codes and regulations governing sales construction installation and or use of products for certain purposes which may vary from those in neighbouring areas While Dayton attempts to assure that its products comply with such codes it cannot guarantee compliance and cannot...

Page 4: ...PTFE 1 11 801A 11 Screws 304SS 8 12 801A 12 Crank Arm Aluminium 1 13 801A 13 Handle Nylon 1 14 801A 14 Handle rivet Steel 1 15 801A 15 Nut Steel 1 16 801A 16 Hexagon bolt Steel 1 17 801A 17 Adapter Screw Aluminum 304SS 1 18 801A 18 Thumb Screw Steel 304SS 1 19 801A 19 Suction tube 304SS 3 20 801A 20 Spout 304SS 1 4 Ordering Spare Parts Parts List Part No 801A NSW TEL 02 9939 0711 FAX 02 9939 0411 ...

Page 5: ...p from side with suction discharge ports in vertical position and on right hand side Reposition rotor by grasping covers and sliding towards 3 o clock position Do not use excessive force Hold in position and retighten cover bolts 3 Suction line above liquid Suction line end must remain completely below fluid surface 4 Damaged worn pump parts Remove pump cover and inspect for broken or worn parts C...

Reviews: