Visit our website at
www.alemlube.com.au
or
www.alemlube.co.nz
NSW/ACT
TEL: (02) 9677 1555
FAX: (02) 9675 1155
QLD/PNG
TEL: (07) 3204 9166
FAX: (07) 3204 1224
VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266
WA
TEL: (08) 9302 4199
FAX: (08) 9303 2095
SA/NT
TEL: (08) 8241 7111
FAX: (08) 8241 7011
NZ
TEL: (09) 447 1007
FAX: (09) 447 1008
5
Mobile Waste Oil Drainer / Extractor
OWNER’S TECHNICAL MANUAL
30100
EJECTION
Tank Emptying
(FIG 9 & FIG 10)
When the oil retained in tank is near full (FIG.10), you need to eject oil out
into a disposal tank and resolve the waste oil accordingly to the instruction
of local government.
1.
Turn off all the valves.
2.
Hold the ejection hook and insert it into the external disposal tank.
3.
Connect the air compressor with the air inlet 4.
4.
Turn on wing valve 5 for oil ejection.
5.
Turn on the mini ball valve 4 gradually, adding tank pressure, turn off air
compressor when pressure reach to desired pressure. (The safety valve
will automatically release pressure when the tank pressure reach about
1.0 bar/14PSI, turn off the mini ball valve 4 immediately and quickly drop
the tank pressure below 1.0bar/14PSI).
6.
Cut off air source after ejection, empty tank pressure and turn off all valves.
Note: Discharge Residual oil from Residual oil cup when it reaches
STOP sign. (FIG.10)
WARNING
1.
Please hold the end of Ejection Hook to avoid waste oil spattering
out, cause an injury of eye, dirty of clothes.
2.
Before disconnect extraction/ejection tube with fast couple (male),
making sure no any pressure existed in the tank.
Otherwise, oil will spray out.
TROUBLE SHOOTING
1.
Vacuum gauge don’t work
• Check the air pressure: standard air pressure through air inlet valve should
between 87~116PSI /6~8bar; Air consumption is about 200L/Min.
• Make sure all the valves are on the correct place.
• Check vacuum operator-to-tank seal.
2.
There is a figure showed on the vacuum gauge but the machine don’t
working and extracting
• Check extraction hose-to-probe seal.
• Temperature of waste oil is too low or not? (ordinary temperature of oil should between 40~60℃.)
• Extract grease oil or other oil with high density, which is, avoided.
• Make sure that extraction pipe open.
• Make sure that extraction pipe do not block off and probe don’t touch the bottom of tank.
• Make sure that the silencer haven’t been blocked.
INSPECTION, MAINTENANCE & CLEANING
1.
Before each use, inspect the general condition of the machine Check for loose screws, air and oil leakage,
misalignment or binding of moving parts, cracked or broken parts, and any other condition that may affect
its safe operation. If abnormal noise or vibration occurs, have the problem corrected before further use.
Do not use damaged equipment.
2.
Periodically recheck all hoses, valves, nuts, bolts, and screws for tightness.
3.
For a long time to use, please check the adapter/ seal ring of the adaptors for leakage.
4.
It’s necessary to drain the waste oil as soon as possible in case of the corroding of tank.
5.
Store in a clean and dry location.
6.
All maintenance and repairs must be completed by a qualified technician.
Fig 9
Fig 10