Alemite 7716-D1 Service Manual Download Page 6

 

SER 7716-D1

 

High-Pressure Measuring Control Valve

 

Revision (11-95)

6

Alemite Corporation

 

4

5

3

2

1

5

4

3

2

6

7

8

9

10

12

15 16 17

18

20

19

24

38

39

35

36

37

40

13 14

13

14

26
21
25

22
23

27

28

34
33

31

32

30
29

11

NOTE: The earlier units contain

a leather washer (not illustrated)

that is no longer required.

 

23. Unscrew Nut (

 

10

 

) from Packing Screw (

 

8

 

).

24. Unscrew the Packing Screw and Adjusting Screw 

assembly from the Valve Body.

25. Remove O-Ring (

 

2

 

), V-Packing (

 

9

 

), and Adjusting 

Screw (

 

12

 

) from the Packing Screw.

26. Push the Measuring Piston assembly from the Valve 

Body.

 

IMPORTANT: Backup Ring (

 

5

 

) is of Teflon

construction. The earlier model contained
leather washers.

 

27. Remove O-Ring (

 

3

 

), V-Block Packing (

 

4

 

), and Backup 

Ring (

 

5

 

) from each end of Measuring Piston (

 

6

 

).

28. Unscrew Plug (

 

11

 

) from the Valve Body as required.

 

Figure 3

 

High-Pressure Measuring Control Valve Model 7716-D1 - Section View

 

Refer to 

 

Figure 2

 

 Parts List

 

Clean and Inspect

 

NOTE

 

: Use a repair kit for replacement

parts. Make sure all the components are
included in the kit before discarding used
parts.

  1. Clean all metal parts in a modified petroleum-based 

solvent. The solvent should be environmentally safe.

  2. Inspect all parts for wear and/or damage.

• Replace as necessary.

  3. Closely inspect the mating surfaces of all components 

for any imperfections. Ensure a smooth and clean 
contact is obtained when assembled.

 

EXAMPLE

 

: Make sure the halves to Slide

Valve and Seat Assembly (

 

22

 

) mate properly. 

 

for Parts Identification

Summary of Contents for 7716-D1

Page 1: ...f 5 000 345 1 28 4 Table 1 Model 7716 D1 Specifications Description and Operation The model 7716 D1 control valve handles fibrous light and heavy greases including semifluid and fluid lubricants This...

Page 2: ...sion 11 95 2 Alemite Corporation 35 41 14 25 26 1 2 2 8 9 10 3 4 5 6 5 4 3 7 11 12 13 15 21 22 23 24 16 17 18 19 20 1a Accessory Item 27 28 29 30 31 34 33 32 13 14 36 37 38 39 40 Figure 2 High Pressur...

Page 3: ...1 4 20 x 5 8 1 305413 12 20 Nut 1 4 20 1 305414 37 21 Gasket Valve Seat 1 305415 24 22 305780 Valve and Seat Assembly Slide 1 305416 38 23 305426 Guide Valve 1 305418 35 24 305415 Lever 1 305419 21 2...

Page 4: ...Preventive Maintenance Refer to section entitled Overhaul for details on the procedures necessary to perform maintenance Part Number Description 6778 Rigid Flexible Extension Table 2 High Pressure Me...

Page 5: ...k Washers 25 that secure the Seat to the Valve Body 21 Remove the Seat and Gasket 21 from the Valve Body Adjusting Screw Assembly 22 Unscrew Plug 1 from the Valve Body Remove O Ring 2 from the Plug Ov...

Page 6: ...ntained leather washers 27 Remove O Ring 3 V Block Packing 4 and Backup Ring 5 from each end of Measuring Piston 6 28 Unscrew Plug 11 from the Valve Body as required Figure 3 High Pressure Measuring C...

Page 7: ...e dispensed 12 Install V Packing 9 lip end first onto the stem of the Adjusting Screw 13 Screw Nut 10 onto the Packing Screw 14 Screw the Packing Screw assembly into the Valve Body Tighten securely 15...

Page 8: ...e sure the knurled end of the Pin is flush with the Valve Body 37 Screw Setscrew 37 into the Lever 38 Install Nut 36 onto the Setscrew Do not tighten Setscrew Adjustment Lever Free Play Adjust the Set...

Page 9: ...e control valve and system If the control valve does not dispense the product refer to the Troubleshooting Chart With the Lever in the released position no product should appear at Coupler 41 If produ...

Page 10: ...roduct to enter Port A and fill Chamber A At the same time the slide valve aligns Port B with Port D This allows product to flow from Chamber Bvia Port B and intoPort D to discharge Lever Released Whe...

Page 11: ...akage at Extension 40 Initial tightening not sufficient 1 Tighten Extension 40 into Valve Body 7 2 Apply Teflon tape to Extension threads Leakage at rear end of Coupler 41 Initial tightening not suffi...

Page 12: ...SER 7716 D1 High Pressure Measuring Control Valve Revision 11 95 12 Alemite Corporation...

Reviews: