37
PLAN AN ESCAPE ROUTE:
• Make a map and mark all locations of doors and windows and a possible escape route. Note
that you may need an escape ladder on high floors.
• Ensure everyone in the house knows the sound the smoke alarms produce and regularly prac-
tice use of the escape route.
• Leave the house immediately according to the plan when hearing the alarm. Every second
counts: so respond quickly. If you do not notice smoke or heat, check if everyone in the house
is in a secure location.
• Do not open any doors without feeling wether the door is warm or if there is smoke coming
from underneath the doors. If it is, do not open that door. If the door is cold, put your shoulder
firmly against the door and open it a small amount to check for any heat or smoke first.
• If there is much smoke, keep low and take shallow breaths, preferably through a moist towel.
Call the fire department as soon as you are safe outside.
BATTERY REPLACEMENT
The battery has a lifespan of 10 years. After 10 years you should replace the entire product because
the battery cannot be replaced.
SENSOR REPLACEMENT:
The sensor has a lifespan of 10 years. After 10 years you should replace the entire product because
the sensor cannot be replaced.
If the yellow LED illuminates within these 10 years, please refer to the paragraphs Reason for
sensor fault and Sensor fault caused by chemical gases.
SPECIFICATIONS:
Power supply:
3VDC (EVE CR17450 INCL., non-replaceable)
Sensitivity and time:
30ppm CO, alarm is not activated within 120 minutes
50ppm CO, alarm is activated within 60~90 minutes
100ppm CO, alarm is activated within 10~40 minutes
300ppm CO, alarm is activated within 3 minutes
0.09~0.15 dB/m smoke, alarm is activated immediately
standby consumption:
<20µA
consumption at alarm:
<20mA
Sound pressure at alarm: >85dB (1m distance)
Environmental conditions: 0~40°C, 30~93% humidity
Storage conditions:
-20
º
C - 50
º
C, 10~95% humidity
Dimensions: 135*40mm
Weight: 185g
Type:
Type B (unchecked output)
Smoke sensor:
Photo-electric
CO sensor:
Electro-chemical
Conforms to:
EN14604-2005 + AC:2008
EN50291-1:2010 + A1:2012