background image

Warranty

The manufacturer warrants for 3 years from the date of purchase, the product to be 

free from defects in workmanship or material (excluding recalibration) under normal 

use. The manufacturer’s obligation under this warranty is limited to replacing, 

adjusting or repairing the unit if returned along with proof of purchase. This warranty 

is void if the unit has been tampered with, damaged or abused in any way.

Warnings

a.  Allow at least 20 minutes after eating or drinking before testing. Any type of 

     alcohol remaining in the mouth of saliva may interfere with proper testing

     and requires about 20 minutes to disperse. This includes alcohol-based 

     mouthwash or similar products. 

b.  Avoid testing in high wind conditions or in poorly ventilated or enclosed spaces. 

     Poor ventilation may also lengthen the time required for warm up between tests. 

c.  Do not blow smoke, saliva or other contaminants into the mouthpiece, as the

     sensor may become damaged. Wait at least 20 minutes after smoking before 

     conducting a test. 

d.  Do not use the breathalyser as a tool to drink and drive. 

e.  Do not blow fluid into the instrument as it will damage the sensor and void your

     warranty.

f.   Do not store in an extreme environment where high temperature or high

     humidity exists. Keep out of the reach of children.

g.  To maintain accuracy, we recommend professional recalibration every 6 months. 

h.  Blood alcohol concentration can continue to rise for up to 2 hours after the

      cessation of drinking. If a caution result or a result is close to the designated    

     BAC, it is recommended to wait and retest after 20 minutes.

i.   It can take 10 hours or more for the alcohol level to return to a zero after a high

     blood alcohol level has been reached. A further test should be carried out later   

     in the day of the following morning. 

j.   User-serviceable batteries safety: 

•  Do not dispose of batteries in a fire.

•  Do not recharge a battery unless it is specifically marked “rechargeable”.

•  Do not expose or batteries to heat source.

•  Do not mix old and new batteries, or mix different types or makes of batteries.

•  Do not allow children to play with the batteries.

Summary of Contents for ZENITH+

Page 1: ...Industrial Grade Fuel Cell Breathalyser Version 5 1 Updated August 2021 ...

Page 2: ...hope you enjoy owning your AlcoSense Zenith breathalyser If you have any questions regarding the unit or want to speak with us further please visit andatech com au or call 1300 800 200 between 9am and 5pm Monday to Friday Components Introduction Hook for using personal mouthpiece Mouthpiece Slot Power Button Digital LCD Display Battery cover Groove for opening cover Personal mouthpiece Mouthpiece ...

Page 3: ...mouthpiece Please note Holding the power button gives you the total number of uses and the last test results The breathalyser will turn off automatically when not in use Specifications Indication of BAC Accuracy Warm up Time Response Time Use mouthpiece Sensor Type Power Supply Weight Dimensions mm Calibration Ambient Conditions 0 000 to 0 200 BAC 0 005 at 0 050 BAC 5 seconds 4 minutes Within 10 s...

Page 4: ...ng and steadily into the mouthpiece The battery power is low Please replace the batteries with new alkaline batteries If you test over 1000 tests the Zenith will display the CAL sign for sec onds before warming up The CAL sign will provide the appropriate time for calibrating the sensor System error Please send the breathalyser back to the supplier for repair System error Please send the breathaly...

Page 5: ...least 20 minutes after smoking before conducting a test d Do not use the breathalyser as a tool to drink and drive e Do not blow fluid into the instrument as it will damage the sensor and void your warranty f Do not store in an extreme environment where high temperature or high humidity exists Keep out of the reach of children g To maintain accuracy we recommend professional recalibration every 6 ...

Page 6: ...rts and labour The benefits conferred by this warranty are in addition to all rights and remedies in respect of the product that the consumer has under the Trade Practices Act and similar state laws Proof of Purchase This warranty is valid for the original purchase and is not transferable Please keep your purchase docket or receipt as proof of purchase and as proof of date on which the purchase wa...

Page 7: ... This warranty does not cover Calibration costs Any defect caused by an accident misuse abuse improper operation lack of reasonable care unauthorised modification loss of parts tampering or attempted repair by a person not authorised by the distributor Any product that has been damaged by a lightning strike either directly or indirectly or a main power surge or liquid ingress The product if it is l...

Page 8: ... which in turn only gives an approximately indication of blood alcohol concentration In these circumstances the user of this product should not rely on the information provided thereby as an accurate indication of his blood alcohol concentration or of his level of intoxication or of his fitness to drive and in particular should not take any action in reliance on such information as the product can...

Page 9: ...at my andatech com au Alternatively fill out this form and forward to the address below along with a copy of your proof of purchase Andatech Pty Ltd PO BOX 3038 Nunawading VIC 3131 Australia Product Serial Number Date of Purchase Place of Purchase Surname Given Name Address Suburb Postcode State Contact no Email AlcoSense Zenith ...

Page 10: ...Product Registration Register online at my andatech com au or complete this form and forward to Andatech Pty Ltd PO BOX 3038 Nunawading VIC 3131 Australia Please Affix Stamp here ...

Reviews: