CALIBRATING A HANDSET

Calibration is possible either with a download station or by maintenance code (without a download 

station).
Do A or B.

A. WITH A DOWNLOAD STATION

1. 

Connect the download station to a power source. 

2. 

Disconnect the handset from the ECU.

3. 

Connect the download station to the handset with a coiled cable and V3/L OEM adapter. 

The handset automatically powers on.

4. 

Press the left button on the handset to select Cal

The current handset date and time are displayed.

5. 

In the Date/Time screen, press OK to confirm - the SELECT TYPE menu is displayed.  

NOTE: If a tachograph is installed, the date and time cannot be changed.

6. 

Choose Dry Gas and press OK. The SELECT UNITS menu is displayed. 

7. 

Select BrAC and press OK. The SELECT DIGITS menu is displayed.

8. 

Select 2 digits and press OK. The SELECT VALUE menu is displayed.

Skip the next section and read: “Calibrating a handset (continued).”

B. BY MAINTENANCE CODE (NO DOWNLOAD STATION)

NOTE: The handset must be connected to the ECU.

1. 

Power the handset on by holding down any navigation button.

2. 

Access the menu screen by pressing and holding the left button.  

NOTE: Where available, press and hold the right navigation button to exit a current 

screen / menu.

3. 

Press Next to scroll to System Maintenance, and press Select

4. 

Input the daily System Maintenance Code (obtained from ITE). To do so:

•  Press [+] / [-] repeatedly to increment / decrement a digit.
•  Press Next to move the cursor to the next digit.

5. 

With the code entered, press Next to move the cursor to OK, and press Select.

6. 

In the service menu, press Next to go to Calibrate, and press Select.

7. 

In the Date / Time screen, do I or II

I. 

If the date and time are correct, press OK – the SELECT TYPE menu is displayed. 

II. 

If the date or time is incorrect, change as follows:

NOTE: If a tachograph is installed, the date and time cannot be changed. 

a. Press Set to enter the Set Clock screen. 
b. Press [+] / [-] repeatedly to increment / decrement a digit.
c.  Press Select to move the cursor to the next field.

Summary of Contents for L OEM

Page 1: ...Calibration manual Alcohol gas standard ...

Page 2: ...s International Inc and are used under license Alcohol Countermeasure Systems is the trading style of Alcohol Countermeasure Systems Corp 2013 Alcohol Countermeasure Systems The information disclosed in this document is the valuable property of Alcohol Countermeasure Systems and all copyright and other proprietary rights to this document are reserved No reproduction of this document is permitted w...

Page 3: ...d be avoided Examine the canister and valve for any damage and the expiration date on the label Observe all cautions and safety warnings found on the canister Never remove or alter canister labels Never modify the delivery tube in any way Always remove the valve and install the protective cap on cylinders when not in use Store cylinders in a cool well ventilated area away from sources of heat EQUI...

Page 4: ...handset continued B BY MAINTENANCE CODE NO DOWNLOAD STATION NOTE The handset must be connected to the ECU 1 Power the handset on by holding down any navigation button 2 Access the menu screen by pressing and holding the left button NOTE Where available press and hold the right navigation button to exit a current screen menu 3 Press Next to scroll to System Maintenance and press Select 4 Input the ...

Page 5: ...is enters the Altitude menu Altitude is preset to 0 meters 2 Determine the altitude of your exact location NOTE Find exact altitude online Altitude may vary within general region or city always use exact value 3 If your altitude is 100 m or lower leave at 0 m Press OK 101 m or higher press to adjust value increases by increments of 200 m Round to the nearest increment see table at back Press Accep...

Page 6: ...calibration is complete If 3 or 4 tests are required a Calibration OK message is displayed when calibration is complete 8 Do I or II I For calibration with download station disconnect the handset from the download station and connect back to the ECU II For calibration without download station press the right button to finish there is also the option to retry by pressing the left button CALIBRATION...

Page 7: ...rrectly entered in the Select Value menu The alcohol gas standard is expired All connections to and from the gas valve are not secured properly The value entered in Altitude menu is incorrect ALTITUDE REFERENCE TABLE The altitude adjustment is in increments of 200 meters Round the altitude up or down to the closest value as follows IF ALTITUDE IS THEN SET TO 0 100 m 0 101 300 m 200 301 500 m 400 5...