Alcolock L OEM Calibration Manual Download Page 2

Alcohol Countermeasure Systems Corp
60 International Boulevard
Toronto, Ontario  M9W 6J2  CANADA
T +1 416 619 3500 
F +1 416 619 3501
[email protected] 
acs-corp.com

ACS, ALCOHOL COUNTERMEASURE SYSTEMS, ALCOLOCK and “The Molly” are trademarks of Alcohol 

Countermeasure Systems (International) Inc. and are used under license. Alcohol Countermeasure Systems is 

the trading style of Alcohol Countermeasure Systems Corp.

© 2013 Alcohol Countermeasure Systems
The information disclosed in this document is the valuable property of Alcohol Countermeasure 

Systems and all copyright and other proprietary rights to this document are reserved. No reproduction 

of this document is permitted without the prior written consent of Alcohol Countermeasure Systems.

Summary of Contents for L OEM

Page 1: ...Calibration manual Alcohol gas standard ...

Page 2: ...s International Inc and are used under license Alcohol Countermeasure Systems is the trading style of Alcohol Countermeasure Systems Corp 2013 Alcohol Countermeasure Systems The information disclosed in this document is the valuable property of Alcohol Countermeasure Systems and all copyright and other proprietary rights to this document are reserved No reproduction of this document is permitted w...

Page 3: ...d be avoided Examine the canister and valve for any damage and the expiration date on the label Observe all cautions and safety warnings found on the canister Never remove or alter canister labels Never modify the delivery tube in any way Always remove the valve and install the protective cap on cylinders when not in use Store cylinders in a cool well ventilated area away from sources of heat EQUI...

Page 4: ...handset continued B BY MAINTENANCE CODE NO DOWNLOAD STATION NOTE The handset must be connected to the ECU 1 Power the handset on by holding down any navigation button 2 Access the menu screen by pressing and holding the left button NOTE Where available press and hold the right navigation button to exit a current screen menu 3 Press Next to scroll to System Maintenance and press Select 4 Input the ...

Page 5: ...is enters the Altitude menu Altitude is preset to 0 meters 2 Determine the altitude of your exact location NOTE Find exact altitude online Altitude may vary within general region or city always use exact value 3 If your altitude is 100 m or lower leave at 0 m Press OK 101 m or higher press to adjust value increases by increments of 200 m Round to the nearest increment see table at back Press Accep...

Page 6: ...calibration is complete If 3 or 4 tests are required a Calibration OK message is displayed when calibration is complete 8 Do I or II I For calibration with download station disconnect the handset from the download station and connect back to the ECU II For calibration without download station press the right button to finish there is also the option to retry by pressing the left button CALIBRATION...

Page 7: ...rrectly entered in the Select Value menu The alcohol gas standard is expired All connections to and from the gas valve are not secured properly The value entered in Altitude menu is incorrect ALTITUDE REFERENCE TABLE The altitude adjustment is in increments of 200 meters Round the altitude up or down to the closest value as follows IF ALTITUDE IS THEN SET TO 0 100 m 0 101 300 m 200 301 500 m 400 5...

Page 8: ...CAM ENG 60 000567 A 2013 ...