13 — System timing and timing sources
2902 MainStreet Technical Practices
13-5
May 2002 90-2906-01
Figure 13-1 Synchronization display
Table 13-1 describes the entries that can appear under Status.
Table 13-1 Sychronization source status descriptions
2902 MainStreet 82211-ab-cd NEWYORK Alarms:2 09-JAN-1997 1:00P
Auto Net Sync: Disabled Node Class: 15 Current Class: 15
Number Source Recovery Class Threshold Status
1 P1 Auto 14 5 Not Ready
2 P2 Auto 14 5 Not Ready
Current source of synchronization is Default (Free Run)
CONFIG SYNCH
1-SRC_NUM 2- 3- 4-NODE_CLASS 5-
6- 7- 8-CANCEL 9-QUIT 0-
Status
Description
Disabled
The source in manual recovery has failed.
The system has unsuccessfully attempted timed recovery to the source.
The source has exceeded the permissible failure rate (set under THRESHOLD).
The source was disabled (by selecting DISABLE). The source is in the default state.
The source was in the Cannot Lock state and an unsuccessful attempt to recover to
the source was made.
Not Ready
The source is not available for system timing.
Ready
The source is available for system timing.
Current
The source is providing system timing.
Auto Rec
The source has failed and will be used by the system as soon as it becomes available.
Time Rec
The source has failed and the system is checking at timed intervals to see if it is
available to provide system timing.
Cannot Lock
The system is unable to take timing from the source. It attempts to retake timing from
the source shortly after this state is entered.
Summary of Contents for MainStreet 2902
Page 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Page 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 343: ......
Page 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...