background image

...................................................................................................................................................................................................

4

The 9772 Wi-Fi Service Controller pushes the access point configuration. During this
operation the both Wi-Fi LEDs will blink quickly until the WLANs are mapped to radios
marked by a slow blinking Wi-Fi status indicator.

The Wi-Fi service may be operational on a single frequency (2.4GHz or 5GHz) or
simultaneously on the both frequencies.

...................................................................................................................................................................................................

5

After a period in the same state, that is parameterized, all the Wi-Fi LEDs are switched
off.

...................................................................................................................................................................................................

6

Return to the

Step 9

.

The Wi-Fi LEDs initialization steps are summarized in the following table:

Table 3-1

Wi-Fi Status LED initialization states

Step Description

State

5G LED

2G LED

1

Power-up or reload

BOOTING

Solid On

Solid On

2

9962 MSEC v1.0 access point tries to get
adopted by 9772 Wi-Fi Service Controller

ADOPTING

Slow
blinking

Off

3

(optional) 9772 Wi-Fi Service Controller
pushes a software upgrade

UPGRADING

Off

Slow
blinking

4

The 9772 Wi-Fi Service Controller pushes
the 9962 MSEC v1.0 access point
configuration

CONFIGUR-
ING

Fast
blinking

Fast
blinking

5

WLAN are mapped to radios: normal
service

OPERA-
TIONAL

5GHz
service:
Slow
blinking

2.4GHz
service:
Slow
blinking

6

After 30

1

minutes in the same state

HIDING

Off

Off

Notes:

1.

configurable from 15 to 1440 minutes.

Alcatel-Lucent 9962 Multi-standard Enterprise Cell v1
commissioning

Commissioning process

....................................................................................................................................................................................................................................

....................................................................................................................................................................................................................................

3-6

Alcatel-Lucent 9962 MSEC v1.0

3MN-02001-0002-RJZZA

Issue 2.01

September 2015

P

RELIMINARY

P

RELIMINARY

E

N D

O F

S T E P S

...................................................................................................................................................................................................

Summary of Contents for 9962

Page 1: ...Title page Alcatel Lucent 9962 Multi standard Enterprise Cell v1 Hardware Installation 3MN 02001 0002 RJZZA Issue 2 01 September 2015 P RELIMINARY P RELIMINARY...

Page 2: ...s of Alcatel Lucent All other trademarks are the property of their respective owners The information presented is subject to change without notice Alcatel Lucent assumes no responsibility for inaccura...

Page 3: ...ation Overview 1 1 1 1 Structure of safety statements 1 1 1 1 General hazard statements 1 3 1 3 Basic safety aspects 1 7 1 7 2 Alcatel Lucent 9962 Multi standard Enterprise Cell v1 installation Overvi...

Page 4: ...1 Post installation information 4 2 4 2 A Product conformance statements Overview A 1 A 1 United States A 1 A 1 Environmental requirements A 3 A 3 Glossary Index Contents iv Alcatel Lucent 9962 MSEC v...

Page 5: ...List of tables 3 1 Wi Fi Status LED initialization states 3 6 3 6 Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2015 v P RELIMINARY P RELIMINARY...

Page 6: ...List of tables vi Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2015 P RELIMINARY P RELIMINARY...

Page 7: ...s 2 13 2 13 2 7 9962 MSEC v1 0 external antenna connector 2 14 2 14 2 8 9962 MSEC v1 0 integrated antennas 2 16 2 16 2 9 9363 access point replacement 2 17 2 17 2 10 Backhaul connection Star configura...

Page 8: ...List of figures viii Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2015 P RELIMINARY P RELIMINARY...

Page 9: ...document Start with the first chapter and work through the manual to the end Once you have done this you will have carried out the hardware installation completely and in the proper sequence Before in...

Page 10: ...For more information on Alcatel Lucent 9962 Multi standard Enterprise Cell v1 Technical Description and Troubleshooting Guide 3MN 02001 0003 DEZZA http www alcatel lucent com The 9962 MSEC v1 0 Basic...

Page 11: ...4 2485 See the country specific exit codes listed here These numbers apply for document support only For details about product hardware software and technical support see the section Technical support...

Page 12: ...About this document xii Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2015 P RELIMINARY P RELIMINARY...

Page 13: ...is document Contents Structure of safety statements 1 1 General hazard statements 1 3 Basic safety aspects 1 7 Structure of safety statements Overview This topic describes the components of safety sta...

Page 14: ...ndicates an extremely hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious inju...

Page 15: ...ntact with energized parts can cause serious injury At least one other trained person must be in attendance who can immediately and safely disconnect the system if necessary This second person must be...

Page 16: ...NG Laser hazard The light from laser and high radiance LED s may cause eye damage if absorbed by the retina In the US consult ANSI Z136 2 in Europe consult IEC 60825 Safety of laser products for guida...

Page 17: ...the network element during transport especially on moving from outside to closed rooms Condensation can cause malfunctioning of the circuit packs Ensure that circuit packs and shelves have reached roo...

Page 18: ...les on a conductive floor surface or conductive work mat Leave the modules in their original packaging until ready for use Make sure there is no difference in potential between yourself the workplace...

Page 19: ...ing both general instructions and the stated methods for avoiding hazards The system must not be operated unless safety is guaranteed Any faults and errors that might affect safety must be reported im...

Page 20: ...e as part of the building installation Installation must include an independent frame ground drop to the building ground Refer to the Hardware Installation Guide For information on correct mounting in...

Page 21: ...n as applicable Use caution when installing or modifying telecommunication lines Never install telecommunication wiring during a lightning storm Never install telecommunication connections in wet loca...

Page 22: ...Safety and general information Basic safety aspects 1 10 Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2015 P RELIMINARY P RELIMINARY...

Page 23: ...2 MSEC v1 0 is a wireless access point using licensed spectrum delivering improved network reach and increased capacity while offloading traffic from the macro network As part of the Alcatel Lucent 93...

Page 24: ...v1 0 access point Device placement The Alcatel Lucent 9962 Multi standard Enterprise Cell v1 has been designed to be deployed in any and only indoor environment either in private places such as busine...

Page 25: ...62 MSEC v1 0 is provided in a cardboard box with the following contents The 9962 MSEC v1 0 access point A mounting kit wall or ceiling including M5 steel screws to be used with N 2 driver A quick star...

Page 26: ...r change the setting Installation location The product shall be installed at a location where the radiating antenna can be kept 30 cm from nearby person in normal operation condition to meet regulator...

Page 27: ...evice be fastened to the wall or ceiling with appropriate mounting hardware Important It is the responsibility of the customer to provide any necessary support material and structures to ensure that t...

Page 28: ...mount that requires two 2 stick antennas per 9962 MSEC v1 0 access point Figure 2 2 9962 MSEC v1 0 mounting plate Alcatel Lucent 9962 Multi standard Enterprise Cell v1 installation Mounting guideline...

Page 29: ...is configuration the antenna port isolation for external antennas is 20dB minimum Option 1 Alcatel Lucent 9962 Multi standard Enterprise Cell v1 installation Mounting guidelines Alcatel Lucent 9962 MS...

Page 30: ...tify the carrier that delivered the unit and contact your Alcatel Lucent representative Record the 18 digit serial number before mounting the 9962 MSEC v1 0 access point Alcatel Lucent 9962 Multi stan...

Page 31: ...as on the 9962 MSEC v1 0 access point Note The wall mount implies that the access point is vertically installed with the stick antennas pointing upwards not downwards or sideways The stick antennas ca...

Page 32: ...After site survey these mounting accessories must be procured locally 5 Connect the cables Refer to the procedure Cabling p 2 19 for details 6 Attach the 9962 MSEC v1 0 to the mounting plate as follow...

Page 33: ...the customer attach the lock to secure the 9962 MSEC v1 0 to the mounting plate The following graphic shows the mounting plate attached to the back of the 9962 MSEC v1 0 Figure 2 4 Notch groove and l...

Page 34: ...s ladder scaffold manlift roof etc follow safe work practices and wear appropriate fall protection equipment Figure 2 5 Mounting plate on the 9962 MSEC v1 0 access point Alcatel Lucent 9962 Multi stan...

Page 35: ...dicated grooves Put the cover back on the integrated antenna connectors 2 At the selected installation location mark the points on the ceiling for the four 4 fixing holes using the holes in the mounti...

Page 36: ...nal antennas to the dedicated SMA connectors 7 Attach the 9962 MSEC v1 0 to the mounting plate as follows 1 Line up the four 4 grooves in the back of the 9962 MSEC v1 0 with the four 4 notches protrud...

Page 37: ...new 9962 MSEC v1 0 as the mounting plates of the two products require the same installation The 9363 access point supporting installation inside false ceiling the following procedure lists the steps...

Page 38: ...cent 9363 Metro Cell Indoor V2 1900 850MHz and 2100MHz Installation and Commissioning 3MN 01121 0301 RJZZA 4 Attach the 9962 MSEC v1 0 mounting plate at the place left free by the 9363 access point Fi...

Page 39: ...mper cables used to connect external antennas to 9962 MSEC v1 0 Select the appropriate jumper cables and connect the external antennas to the dedicated SMA connectors Figure 2 9 9363 access point repl...

Page 40: ...3 Then screw the four 4 screws provided in the ceiling mounting kit to attach the 9962 MSEC v1 0 to the mounting plate 8 If locks have been ordered by the customer attach the lock to secure the 9962...

Page 41: ...n additional data cable is required refer to Daisy chain p 2 27 for details The data cable can be a standard Ethernet cable with RJ45 connector or a fiber cable with an electrical optical transceiver...

Page 42: ...to adapt the cable length by cutting it and mounting the RJ45 connector at the cut end 2 These cables are outdoor cables The tables below list the fiber cables complying with the 9962 MSEC v1 0 access...

Page 43: ...80 80mm 849193586 OPTICAL CABLE 300m 2SM 5 5mm 2LC to 2LC OFNR LS Breakout 80 80mm Notes 1 Select one cable per single mode duplex link Multi mode duplex cables Order codes Description 849193594 OPTIC...

Page 44: ...out 80 80mm 849193719 OPTICAL CABLE 250m 2MM 5 5mm 2LC to 2LC OFNR LS Breakout 80 80mm 849193727 OPTICAL CABLE 300m 2MM 5 5mm 2LC to 2LC OFNR LS Breakout 80 80mm Notes 1 Select one cable per multi mod...

Page 45: ...rs complying with the 9962 MSEC v1 0 SFP port Order codes Description 1AB413590001 SFP GBE 10 100 1000BaseT copper 1AB187280029 SFP GBE 1000BaseLX Single Mode LC connector 1AB187280063 SFP GBE 1000Bas...

Page 46: ...1m SMA Male N Male 1AB414570001 Jumper Type N to SMA 2m SMA Male N Male Power supply The 9962 MSEC v1 0 access point can be powered through DC input power with an AC DC power adapter including an appr...

Page 47: ...a standard router Go to Connect to a standard DSL router p 2 26 and Connect the AC DC power adapter p 2 26 Use PoE supplied by a DSL router with PoE function Go to Connect to a DSL router with PoE fun...

Page 48: ...upply power to the 9962 MSEC v1 0 perform the following steps 1 Route the power supply cable from the 9962 MSEC v1 0 to the supplied AC DC power adapter 2 Connect the power supply cable to the 9962 MS...

Page 49: ...v1 0 3 Finally secure the GPS antenna cable to the wall Daisy chain The 9962 MSEC v1 0 access point can be linked in a daisy chain Fiber links are not allowed in this configuration The daisy chain ho...

Page 50: ...ple of 9962 MSEC v1 0 daisy chain Alcatel Lucent 9962 Multi standard Enterprise Cell v1 installation Cabling 2 28 Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2015 P RELIMIN...

Page 51: ...This chapter describes the 9962 MSEC v1 0 commissioning process The 9962 MSEC v1 0 is self commissioning in the case of single device deployments Contents Commissioning process 3 2 Alcatel Lucent 996...

Page 52: ...roubleshooting Guide 3MN 02001 0003 DEZZA Before you begin The 9962 MSEC v1 0 is intended to be installed and then left unattended so the LED pattern activated in the commissioning process is mainly f...

Page 53: ...cator will blink green 4 Once the software update has completed the 9962 MSEC v1 0 access point will carry out an automatic reboot During reboot the Power indicator will still be blinking green 5 The...

Page 54: ...ing this operation the LTE status indicator will blink red green until the service is operational marked by a solid green LTE status indicator Important In case the configuration supports only one LTE...

Page 55: ...the 9962 MSEC v1 0 tries to get adopted by the 9772 Wi Fi Service Controller and the 5G LED starts blinking slowly The 2G LED related to the 2 4GHz frequency is off 3 This step is optional and occurs...

Page 56: ...D 1 Power up or reload BOOTING Solid On Solid On 2 9962 MSEC v1 0 access point tries to get adopted by 9772 Wi Fi Service Controller ADOPTING Slow blinking Off 3 optional 9772 Wi Fi Service Controller...

Page 57: ...Overview Purpose This chapter describes the post installation activities and checks Contents Post installation information 4 2 Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2...

Page 58: ...ng their routes 2 Verify that all the exterior conduit and cable connections are secure 3 Inspect the site and remove all loose tools materials and parts Post installation activities Post installation...

Page 59: ...Alcatel Lucent Inc could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions This device may not...

Page 60: ...marketed in US must fixed to US operation channels only Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment...

Page 61: ...l Operation 5 C to 50 C 23 F to 122 F Telcordia GR 63 CORE Telcordia GR 3108 CORE ANSI ATIS 0600010 2007 Operating relative humidity Condensing 5 to 95 Telcordia GR 63 CORE Telcordia GR 3108 CORE ANSI...

Page 62: ...Product conformance statements Environmental requirements A 4 Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2015 P RELIMINARY P RELIMINARY...

Page 63: ...sisted GPS D DC Direct Current DNS Domain Name Server DSL Digital Subscriber Line E EU European Union G GE Giga Ethernet GPS Global Positioning System H HDM Home Device Manager Alcatel Lucent 9962 MSE...

Page 64: ...o Frequency RNC Radio Network Controller S SAM Service Activation Manager SFP Small form factor pluggable SMA SubMiniature version A W WCDMA Wideband Code Division Multiple Access Wi Fi Wireless Fidel...

Page 65: ...elines 2 5 D document support xi E environmental requirements A 3 G General hazard statements 1 3 O Orderable items 2 3 P phone numbers for document support xi Post installation 4 2 Pre installation i...

Page 66: ...Index IN 2 Alcatel Lucent 9962 MSEC v1 0 3MN 02001 0002 RJZZA Issue 2 01 September 2015 P RELIMINARY P RELIMINARY...

Reviews: