background image

Automatic Protection Switch

The automatic protection switch (APS) 
enables route protection on E1 level.  
If used, the Alcatel-Lucent 1511 BA 
transmits data via two different E1 
routes. At the receive side, data coming 
from the preferred route is used; if this 
route fails, data is taken from the 
other side. 

Ethernet Switching

On an E1 trail across multiple Alcatel-
Lucent 1511 BA multiplexers, a group 
of 64-kb timeslots (N: 1...31) is reserved 
to carry Ethernet frames. In each Alcatel-
Lucent 1511 BA, one 10/100Base-T LAN 
board (LANtrib) can drop/insert its local 
Ethernet traffic onto these reserved 
timeslots. To connect multiple Ethernet-
based end devices, the LANtrib offers 
five external RJ-45 interfaces. The 
LANtrib also switches LANs across mul-
tiple and distinct Alcatel-Lucent 1511 
BA multiplexers. Switching between 
the local five Ethernet ports runs at 
wire speed.

Technical Specifications

Main Characteristics

•  Compliant with all relevant ITU-T 

recommendations including: 

G.703, G.704, G.706, G.711, G.712, 

G.732, G.784, G.823, G.826, V.28, 

V.35, V.36, and X.21

Clock Synchronization

•  Internal clock (50 ppm)
•  Extracted from E1 port
•  External via 2,048 MHz clock 

(ITU-T G.703 § 10) or 64 kHz 

(G.703 § 1.2.2)

Clock and backup priority rules 

are selectable via configuration 

management.

Mechanical Design

•  Uses same technology as the other 

products in the Alcatel-Lucent 

access product family 

•  Plug-in printed boards with Double 

Euro format. State-of-the-art 

components ensure low power 

consumption and high reliability.

•  Subracks (can be mounted in rack 

or cabinet):
¬ T9 subrack: Width of 120 mm 

(4.72 in.), 240 mm (9.45 in.), 

360 mm (14.17 in.) or 480 mm 

(18.89 in.)

¬ 19-in. subrack:
   -  height: 7U (1U = 44.45 mm, 

1.75 in.)

   -  Can be mounted in a 300-mm 

deep (11.81 in.) ETSI rack

•  ETSI T9 and 19-in. racks:

¬ available in two heights: 

2,200 mm (86.61 in.) (with six 

Alcatel-Lucent 1511 BA subrack 

mounting levels) and 1,800 mm 

(70.87 in.) (with five mounting 

levels)

•  Cabinets: Both indoor and outdoor 

variants available

Power Supply

•  -38.5 V to -72 V DC
•  110/220 V AC ± 20%

Environment

> Operating temperature: -5 C to 

+50 C (23 F to 122 F)

> Transport and storage temperature: 

-40 C to +70 C (-40 F to +158 F)

•  Compliant with:

¬ ETS 300 019-2-1
¬ ETS 300 019-2-2
¬ ETS 300 019-2-3

EMC

•  EMC on rack basis (EMC directive 

89/336/EEG [EN 50081-1, EN 

50082-1])

•  EMC on subrack basis  

(ETS 300-386-1)

www.alcatel-lucent.com

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other 
trademarks are the property of their respective owners. The information presented is subject to change 
without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. 
© 2008 Alcatel-Lucent. All rights reserved. CAR9718080111 (02)

Reviews: