VIDEOPORTERO 2 HILOS | 2-WIRE VIDEO DOOR ENTRY SYSTEMS | VIDÉO-PORTIER 2 FILS
62
5. Program the monitors / telephones from the main entrance panel of
the building.
6. Entrance panel configuration adjustments, see page 69.
Programming steps
1. Move the PROG switch to the OFF position; Return the switch to the
ON position.
2. Press the door open button . The audio will be activated between
the monitor and the main entrance panel.
3. Located on the main street panel, make the call to the apartment
where the monitor to be programmed is located. The entrance panel
will emit a confirmation beep, the monitor has been programmed.
Note:
Once the monitor is programmed, make sure that the PROG switch is in the ON position.
Note:
Maximum time of 1 minute between steps 1,2 and 3. After the maximum time you must
start programming from step 1.
Note:
For another type of monitor/telephone, consult the corresponding manual.
PROG.
OFF
1
PROG.
ON
2
1
2
3