6.4.1
Servo-control board
The TIMEBOX B is available for the following power supplies at choice: 230Vac, 24Vdc/Vac, 12Vdc. When placing your
orders, please specify which power presetting you need: the interface Servo-board shall be prepared and delivered
accordingly.
A 10p flat cable connects the Active One control board to the Servo-board.
Power the Servo-board by the 3p socket J1, according to the following pattern:
230 Vac
24Vac
24Vdc
12Vdc
Pin 3:
line 230Vac
Line 24Vac
+24Vdc
+12Vdc
Pin 2:
neutral
neutral
0Vdc
0Vdc
Pin 1:
GND
GND
6.4.1a Connections to start the equipment by relay transmission of power supply:
Service Line 1 (Pushbutton A): from power supply, connect one end of service Line 1 straight to the relevant actuator (i.e.
electrical motor, solenoid, a.s.o.). Connect the other end to pin 1 (COM 1) of J2 connector.
If operation mode is “normally open”, take the s
witching wire to the 1 actuator from pin 2 (N.O. 1). These wires must be able
to sustain 10 Amps current draw.
If operation mode must be “normally closed”, take the switching wire to the actuator from pin 3 (N.C. 1). If the actuator
works by d.c., take care to connect properly positive and negative poles!
Service Line 2 (Pushbutton B): from power supply, connect one end of service Line 2 straight to the relevant actuator (i.e.
electrical motor, solenoid, a.s.o.). Connect the other end to pin 4 (COM 2) of J2 connector.
If operation mode is “normally open”, take the switching wire to the 2 act
uator from pin 5 (N.O. 2). These wires must be able
to sustain 10 Amps current draw.
If operation mode must be “normally closed”, take the switching wire to the actuator
from pin 6 (N.C. 2).
It is possible to disable coin acceptance in any of the following two ways:
Electronically - Pins 7/8 of green connector J2: provide any Vdc (+) or Vac (line value) to pin 7, and respectively 0Vdc
(-) or Neutral Vac to pin 8.
Mechanically - move to OFF the dip-switches located on the coin acceptor. Move them back to ON when you want to
resume coin acceptance.