10 

(HN) 

END       DD/MM  HH:MM 

time of first day and end time of last day 

Holiday Daily (HD)  DATE     DD/MM-DD/MM 

TIME     HH:MM-HH:MM 

Specific Date Interval for every year, 
Specific time interval 

Holiday Weekly 
(HW) 

DATE     DD/MM-DD/MM 
MON      HH:MM-HH:MM 
TUE        HH:MM-HH:MM 
WED      HH:MM-HH:MM 
……………………………………... 

Specific Date Interval for every year, 
Specific time of the week days 

Specific Normal 
(SN) 

START   DD/MM/YY  HH:MM 
END       DD/MM/YY  HH:MM 

Specific Date Interval, start time of first day 
and end time of last day 

Specific Daily (SD) 

DATE     DD/MM/YY - DD/MM/YY 
TIME     HH:MM-HH:MM 

Specific Date Interval, Specific time interval 

Specific Weekly 
(SW) 

DATE     DD/MM/YY - DD/MM/YY 
MON     HH:MM-HH:MM 
TUE       HH:MM-HH:MM 
WED     HH:MM-HH:MM 
……………………………………... 

Specific Date Interval, , Specific time of the 
week days 

HH:

 Hour Hour, 

MM:

 Minute Minute, 

MM:

 Month Month, 

DD:

 Day Day, 

YY:

 Year Year 

If the “start time” bigger than “end time” in the daily and weekly tariffs,  it’s mean: 00:00 to End Time 
and Start Time to 23:59 

 
 

Tariff Parameters 

Tariff 1 

Tariff 2 

Tariff 3 

………………. 

Tariff 40 

Init Charge (

p

Init Distance (

yard/10

Init Duration (

second/16

Unit distance(

yard/100

Unit time (

second/64

Unit distance fare (

p/10

Unit time fare (

p/10

Unit extra fare (

p/10

 

Tariffs which changed automatically as depends  distance of the journey

 

Tariff 1 

Tariff 2 

Tariff 3 

……………….. 

Tariff 16 

Limit distance (

yard

 

 

 

 

 

Unit distance or unit distance fare 
(

yard/100 or p/10

Unit time or unit time fare 
(

second/64 or p/10

Tariffs which changed automatically as depends  duration of the journey

 

 

Tariff 1 

Tariff 2 

Tariff 3 

………………….. 

Tariff 8 

Summary of Contents for iTAKSI M12

Page 1: ...t provides information to assist in the users Alberen Electronics Limited reserve the right to change the specification of its products without notice If any further information is required please con...

Page 2: ...N EXPRESSIONS WHILE THE TAXIMETER IS ON 5 5 CHARACTER TABLE 5 6 OPENING THE TAXIMETER 6 6 1 OPENING THE TAXIMETER AS ADMIN 6 7 DISPLAY TIME AND DATE 7 8 DISPLAY LAST FARE METER MEASUREMENT AND SPEED 8...

Page 3: ...M12 Taximeter User Guide 2016 Alberen Electronics 3 1 VIEW 1 1 FRONT VIEW 1 2 REAR VIEW...

Page 4: ...M12 Taximeter User Guide 2016 Alberen Electronics 4 2 CABLES 2 1 POWER CABLE 2 2 POWER CABLE WITH SECOND LAMP DRIVE 2 3 PRINTER CABLE...

Page 5: ...ast fare meter counting speed Pass to mode FOR HIRE Change to the previous parameter Decrement digit Enter menu Increment extra fee Pass to sub menu Confirm the changes Cancel time date or speed showi...

Page 6: ...eter 4 User is admin Separate records for every 3 drivers are saved Fourth user admin can see all records Later if any password is entered for the drivers the password menu is shown in the screen afte...

Page 7: ...r is incremented 8 DISPLAY TIME AND DATE There are three formats for showing time date in the taxi meter When button is pressed once in the FOR HIRE position time is shown in the upper screen as at th...

Page 8: ...the screen as at the below When vehicle moved counter starts to count in meters Press again button speed of the vehicle is shown in the screen as at the below If the taximeter doesn t receive speed s...

Page 9: ...y information of the active tariffs can be shown on the taximeter screen at that moment There are three types of the tariffs Normal N Daily D Weekly W The tariffs can be set according to specific date...

Page 10: ...YY MON HH MM HH MM TUE HH MM HH MM WED HH MM HH MM Specific Date Interval Specific time of the week days HH Hour Hour MM Minute Minute MM Month Month DD Day Day YY Year Year If the start time bigger t...

Page 11: ...0 Unit distance or unit distance fare yard 100 or p 10 Unit time or unit time fare second 64 or p 10 Tariffs which changed automatically as depends speed exceeding in the journey Tariff 1 Tariff 2 Tar...

Page 12: ...nnected to the taximeter it can be selected by pressing button again as shown below After selected or pressed button If 10 seconds have passed after button pressed the taximeter will pass to the FOR H...

Page 13: ...m last 20 records are stored about Constant k constant k value date of change and setup device number These parameters can be changed using only the Setup Device Date Constant k date of change of cons...

Page 14: ...e counter on the sub screen Software Information Setu Device Number Software Version At the upper screen it is shown Setup Device Number which has changed the parameters as date constant k etc Softwar...

Page 15: ...of the power cable is connected to the positive pole of the roof lamp other ground pole of the roof lamp is connected chassis of the vehicle If a second roof lamb will be connected to taximeter then...

Reviews: