Sense Lead Harness Connections
4200-106
10-3
Revision 3
10.2
Systems with Dual or Multiple Positive and Negative Posts
Systems that use dual or multiple positive and negative post interconnections require connection of the
sense lead harnesses using the following guidelines. The positive sense lead wires (solid colors) and
negative sense lead wires (white with colored stripe) of the harness attach to the corresponding positive
and negative terminals of the battery in a way that will monitor as many strap connections as possible.
To achieve optimum results, it is recommended that sense leads should be connected as described in
the Figure below and duplicated at each cell for consistent readings. The following illustration shows a
scenario of dual and/or multiple positive and negative posts as described.
Figure 8 - Exposed Dual or Multiple Posts Connections