The rear interconnection board is not designed to withstand mechanical stress. The
wiring must be fastened properly to the frame where the mounting frame is housed to
prevent the rear board from supporting the weight of the cables.
3.7.1. Electrical SDI video connections
All electrical SDI video connections are BNC type. The following suggestions should be
kept in mind when wiring the electrical signals.
BNC connectors used on cables must be suitable for the high frequencies of digital
video signals: it is strongly recommended to use high quality connectors from well
known manufacturers.
All coaxial cable used must be Belden 8281 or similar. This type provides the greatest
lengths because it is used to calculate the equalizers in the DVM3001C02. Cables
carrying signal between the module and the devices should use single piece
construction, avoiding spliced sections with double BNC female or barrel connectors.
If it is necessary to split the cable into two sections the same type of wire should be
used in both sections.
The use of analog video coaxial cables RG-59 type or similar is not recommended for
digital video except for very short distances.
3.7.2. Analog video connections
The analog video outputs use BNC connectors and have an impedance of 75Ω.
For analog video connections a coaxial cable with 75Ω of characteristic impedance
must be used.
15
Summary of Contents for DVM3001C02
Page 2: ...DVM3001C02 ...
Page 4: ...DVM3001C02 ...
Page 7: ...Albalá Ingenieros Manual DVM3001C02 1 3 Block diagram 7 ...
Page 8: ...Albalá Ingenieros Manual DVM3001C02 DVM3001C02 8 ...
Page 16: ...Albalá Ingenieros Manual DVM3001C02 DVM3001C02 16 ...
Page 24: ...Albalá Ingenieros Manual DVM3001C02 DVM3001C02 24 ...
Page 26: ...Albalá Ingenieros Manual DVM3001C02 DVM3001C02 26 ...