Series AFS8202M
Alba Fiber Systems Inc. Specifications are subject to change without notice.
Page 39 6/20/14
www.albafiber.net
Industrial Redundant Managed Ethernet Media Converter with 2 Ports
1 x 10/100/1000BaseT(X) Port, 1 x 1000M SFP Port
Port Configuration seen as following Fig. 30
Fig. 30 Port Configuration
6.4.2 Loop Protection
This page is used to configure Loopback Detection function for each port. Loopback on port will
cause packet storm in switch.
For each port, if Loopback Detection is enabled and Tx Mode is enable, the port is actively
generating loop protection PDU's. If loopback is found, the action could be shutdown port or log
it. The shutdown time could be configured for some period.
PATH
Web
Configuration, Loop Protection
CLI
Loop/Protect>
PARAMETERS
General Settings
■
Enable Loop Protection
◇
Disabled – Disable the Loop Protection (as a whole)
◇
Enabled - Enable the Loop Protection (as a whole)
■
Transmission Time - The interval between each loop protection PDU sent on each port. Valid values
are 1 to 10 seconds.
■
Shutdown Time - The period (in seconds) for which a port will be kept disabled in the event of a