Operating Instructions
2
SPECIFICATIONS
Accuracy*
Clockwise: ±2.5%
Counterclockwise: ±3.5%
Capacity
DTW-265i - 265 in-lb / 30 N-m
DTW-1200i - 1200 in-lb / 145 N-m
DTW-100f - 100 ft-lb / 145 N-m
DTW-250f - 250 ft-lb / 340 N-m
Resolution
DTW-265i - 0.1 in-lb / 0.01 N-m
DTW-1200i - 1 in-lb / 0.1 N-m
DTW-100f - 0.1 ft-lb / 0.1 N-m
DTW-250f - 0.1 ft-lb / 0.1 N-m
Power
AA x 2
Battery Life
110 hours continuous use
Operating Temp.
-10°C ~ 60°C
Storage Temp.
-20°C ~ 70°C
Humidity
Up to 90% non-condensing
Drop Test
3m
Vibration Test
10G
Unit Selection
in-lb, ft-lb, N-m
Gear Teeth
36
Memory
50 readings
*The accuracy of reading value is guaranteed from 20% to
100% of maximum range ± least significant digit. The torque
accuracy is a typical value. Calibration point is at the middle
line of the five anti-slip lines on the rubber handle. For highest
accuracy we recommend a calibration interval of 1 year.