background image

FLOOR PROTECTOR

140 & STOKER STOVE II

FRONT

B

HOPPER

STOKER

&

8"

A

8"

MODEL 140

HOPPER

STOKER

FRONT

8"

18"

18"

INSTALL WITH MINIMUM

CLEARANCE TO WALL

AS SHOWN (IN INCHES)

A= 16" for model 140
8" for Stoker Stove II

B=8" for model 140
16" for Stoker Stove I

Quality Since 1977

STOVE COMPANY

MODEL: 140 PADDLE FEED   FUEL COAL    SERIAL NO.

MODEL 140 AUGER FEED COAL OR WOOD PELLET

U.S. ENVIRONMENTAL PROTECTION AGENCY

MODEL 140 SINGLE/DUAL FEED HEATER IS ONLY FOR BURNING COAL. USE OF ANY OTHER FUEL

EXCEPT FOR COAL IGNITION PURPOSES IS A VIOLATION OF FEDERAL LAW. MODEL 140 AUGER

HEATER IS ONLY FOR BURNING COAL/PELLETS. USE OF ANY OTHER SOLID FUEL EXCEPT FOR

COAL/PELLETS IGNITIONS PURPOSES IS A VIOLATION OF FEDERAL LAW.

ALASKA STOVE COMPANY - LIMITED WARRANTY

PREVENT HOUSE FIRES: INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS AND LOCAL BUILDING CODES

This warranty applies only to the original purchaser.

Purchase must be made through an authorized Alaska
Co. dealer or a representative of the Alaska Co.

The following warranty applies from the date of

purchase. Workmanship of body ten years, castings two
years, gear motor two years, all other electrical parts one
year, glass and ash pan are not warranted.

Warranty does not apply if damage occurs because of

accident, improper handling or operation, abuse, misuse,
rust or corrosion. No unauthorized repair should be
made or attempted.

Freight and labor costs incurred or any authorized,

warranted item are the responsibility of the original
purchaser. All warranty claims must be accompanied
by a copy of the original sales agreement.

To make claims under this warranty. Contact the

dealer from whom you purchased this unit.

In the event the unit must be returned to the factory

for inspection or repairs, the original purchaser must ship
prepaid to:

Alaska Co., 3126 Columbia Blvd., 
Bloomsburg, PA 17815

In order for this limited warranty to be effective and

binding upon Alaska Co. the following section must be
detached, completed and sent by the original owner to
Alaska Co., 3162 Columbia Blvd., Bloomsburg, PA
17815 within 30 days of purchase.

***All liability for any consequential damages from breach of any written or implied
warranties is disclaimed and excluded here from. Some states do not allow the
exclusion or limitations of accidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which
vary from state to state. This warranty is void if you do not return the attached card
within thirty (30) days after the date of purchase.
***A term required by Federal Law.

CHIMNEY TYPE: MINIMUM 6 INCH DIAMETER APPROVED LOW
HEAT RESIDENTIAL TYPE ALL FUEL. CHIMNEY CONNECTOR: 6 INCH
DIAMETER 24 GAUGE BLUE OR BLACK STEEL. INSTALL AT LEAST 8
INCHES FROM WALL AND 6 INCHES FROM CEILING. SPECIAL
METHODS ARE REQUIRED WHEN PASSING THROUGH A WALL OR
CEILING. SEE INSTRUCTIONS AND BUILDING CODES.

Check Box for Model:

Kast Console  III

Channing III

Model 140

Liberty

Auger Feed 140

Name:

Address:

State:

Zip:

Dealer Name:

Serial # (from label):

Purchase Date:

Phone:

Warranty Registration, Cut here and return to: Alaska Company, Inc., 3162 Columbia Blvd., Bloomsburg, PA 17815

CONAM Inspection, Inc. Auburn, MA 01501 STL - 002

Tested 2/97 to ANSI/UL 1482, CSA B366-1979 & ETLM 78-1

ALASKA COMPANY, INC.

BLOOMSBURG, PA 17815

Summary of Contents for 140 AUGER FEED

Page 1: ...with a time feed mechanism The advantage of a constant air feed system over any thermostat type operations are 1 A longer burning season 2 Your fuel burns better 3 The auto heat control box allows you...

Page 2: ...s pinched between the grate and the feeder housing As shown below IMPORTANT Paddle should be greased at least twice per year with standard grease see grease fitting position below Grate gasket should...

Page 3: ...3 FIGURE 1 Grate Air Holes In Grate 5 7 9 11 18 15 CM AF 6 12 20 2 16 21 3 14 17 8 AM...

Page 4: ...ted air tight house may not allow enough combustion air for the proper performance of your stove This can be corrected by slightly opening a window or installing a fresh air inlet Glass Cleaning and C...

Page 5: ...the metal plate welded to the top of your stove NOTE Install screen after stove is lit Use hearth or stove gloves to install screen Top Vent Stove Only This unit is sent to you with a brick attached...

Page 6: ...auto heat box to 3 STEP 2 Light fire as instructed See page 10 STEP 3 Use the high setting for combustion blower when burning coal STEP 4 Hopper lid must be shut and latched for auger feed system to...

Page 7: ...capable of burning rice coal or wood pellets The fuel is fed from the hopper through the auger and out of the burn pot Unburned fuel residue is either blown out of the pot by the 2 speed blower or for...

Page 8: ...Rope Gasket Remove cover tape from adhesive on gasket Place gasket around outside top of blower Locate blower shroud place blower shroud over blower and attach with screws STEP 6 Refer to drawing for...

Page 9: ...dy on stove Be sure your attachment is plumb See Fig 5 STEP 4 Place a length of pipe into Wall Thimble See Fig 4 This pipe should go through wall and into the Flue Liner Do not allow pipe to pass thro...

Page 10: ...g of 1 is approximately a low fire Always operate stoker with both doors closed Always test your gas alarm as per instruction BEFORE YOU CALL US Not Enough Heat Check to see if holes in grate are clog...

Page 11: ...minutes After stove has ventilated adequately place a low watt lit bulb inside stove body This will aid in keeping dampness out of stove NOTE Important If grate has been removed make sure gaskets are...

Page 12: ...sales agreement To make claims under this warranty Contact the dealer from whom you purchased this unit In the event the unit must be returned to the factory for inspection or repairs the original pu...

Reviews: