Alarm Lock Trilogy PDL1300 Programming Instructions Manual Download Page 16

16 

1. New Master Code

 

(User Number 1) 

2. Add/Delete/Change User Codes 2-2000

  

; 1      ;

 

[ _ _ _ _ _ _ ]

           

[ _ _ _ _ _ _ ] 

:

 

   

(New Master Code)                  (Confirm New Master Code) 

; 2      ;

 

[ _ _ _ _ ]

  *              

;

 

[ _ _ _ _ _ _ ] 

:

 

(User Number)                                    (User Code) 

User Number must be between 2 and 2000. 

To delete a code/card, leave the User Code blank and wait for the rapid beeping to stop, then 
to avoid erroneously enrolling Proximity Cards, press and hold 

:

 for three seconds to exit 

Programming Mode.  If more programming is desired, re-enter Programming Mode. 

User Code must be 3-6 digits. 

Each User Code can be thought of as a person.  As long as each person possesses their own 
unique User Code, you can control access to the lock by adding or deleting User Codes.  See 
"Terminology Used in this Manual" on page 6 for more information. 

Master Code must be 6 digits-only. 

Master Code is Keypad Code Access only.

 

Factory Default = 

123456

 

See "Lock Design Overview" on page 5 for more information about Master Codes.

 

 

3

 

 

M

 

USERS

 

Programming Functions 

User 299 is a Non-Pass Code.  This is the only code that will initiate data transfer with the AL-DTM. 

Lock Defaults for 

PDL1300

 

See page 8.  Users added

 

will default to a Group association and a Programming Level as follows: 

 

USER TYPE 

USER NUMBER

 

GROUP DEFAULT  

ASSOCIATION

 

MINIMUM PROGRAM  

LEVEL (see page 6)

 

Master  

(All Programming Abilities) 

Installers  

2 & 3 

none 

4

 (Also 3, 2, 1) 

Managers  

4 - 6 

none 

3

 (Also 2, 1) 

Supervisors  

7 - 9 

none 

2

 (Also 1) 

Print Only Users 

10 - 11 

none 

1

 

Basic Users  

12 - 50 

none 

none 

Basic Users in Group 1 

51 - 100 

none 

Basic Users in Group 2 

101 - 150 

none 

Basic Users in Group 3 

151 - 200 

none 

Basic Users in Group 4 

201 - 250 

none 

Basic Users  

251 - 296 

none 

none 

Quick Enable User 300  

297 

none 

none 

Quick PC Access  

298 

none 

none 

AL-DTM Code 

299 

none 

none 

Service User 

300 

none 

none 

Basic Users 

301-2000 

none 

none 

To program proximity card, 

press 

:

 and present the card. 

Summary of Contents for Trilogy PDL1300

Page 1: ...stems with ProxCard Access OI312A 6 07 345 Bayview Avenue Amityville New York 11701 For Sales and Repairs 1 800 ALA LOCK For Technical Service 1 800 645 9440 Publicly traded on NASDAQ Symbol NSSC ALAR...

Page 2: ...900 deadlatch locks and 1850 1950 4070 MS1850S and MS1950S series deadbolts for narrow stile aluminum doors The PDL1300 features an HID com patible ProxCard reader and a real time clock calendar that...

Page 3: ...page 17 21 User Access Methods Keypad Entered User Codes see pages 12 13 16 ProxCard and ProxKey Keyfob see page 13 User Code and ProxCard For highest security see page 13 Batch Enroll Quickly and eas...

Page 4: ...Mini Banana Plug Connector After you create the program in DL Windows and transfer the program from your computer to an AL DTM transfer the program from the AL DTM to the lock s via a double ended min...

Page 5: ...r lock to start working To begin programming you must first enter something called Program Mode What is Program Mode With hardware hand tools can be used to make fixes or changes With software however...

Page 6: ...ity to use or make changes to the lock What is a Programming Level The Programming Level defines the range of programming tasks a User is allowed to perform The higher the Level the more pro gramming...

Page 7: ...ode that will initiate data transfer with the AL DTM and without allowing the User to pass through the door the User Code for User 299 is not an Access Code An AL PCI cable and an AL DTM first program...

Page 8: ...ers 7 8 and 9 Can only program functions relating to day to day operation Abbreviated as Programming Level 2 Print Only Users Always associated with Users 10 11 Restricted to print audit trails only N...

Page 9: ...essed during code entry hold any key continuously until the error sound is heard 7 short beeps this will clear the entry Re enter the key sequence again All program sequences are followed by the key 2...

Page 10: ...n AL PCI cable You must always enter the User 298 User Code to send or receive data Using DL Windows IBM COMPATABLE LAPTOP OR DESKTOP PC NOTE OBSERVE TAB DIRECTION WHEN INSERTING CABLE INTO LOCK AL PC...

Page 11: ...not known proceed directly to ALTERNATIVE METHOD below Wait for the green light and press until multiple beeps are heard You are now in Program Mode 2 Press 99 000 3 Listen for 6 beeps The lock will r...

Page 12: ...to be 664433 Press 1 664433 664433 Now that the Master Code has been changed there is no need to change it again unless you want to Since you are still in Program Mode you can now proceed directly be...

Page 13: ...process is basically the same 1 Enter Program Mode if not in already 2 Press 2 User Number Enter the User Number you wish to match with the first ProxCard 3 Lock will beep continuously Place a new Pro...

Page 14: ...slowly for up to 10 seconds 2 Present the ProxCard programmed for the same User Number User may enter User Code or present the ProxCard in either order to open the lock The sounder will beep for up to...

Page 15: ...ock See page 21 Function 45 46 Passage Mode Enable Disable See page 21 Function 47 Timed Passage Mode See page 21 Programming Functions Overview Function 48 Enable Passage Mode See page 22 Function 49...

Page 16: ...ess only Factory Default 123456 See Lock Design Overview on page 5 for more information about Master Codes 3 M USERS Programming Functions User 299 is a Non Pass Code This is the only code that will i...

Page 17: ...rogram Mode and pressing 5 1157 008 NOTE Up to 4 Timeout Functions may be pending at any one time An error beep will sound when attempting to program more than 4 Timeout Functions 2 Service Code is a...

Page 18: ...ions Function 12 clears all programmed Schedules and all Timeout Functions To clear All Timeout Functions only see Function 13 below Function 12 will clear all of the following All Schedule Functions...

Page 19: ...ssociation As per the chart on page 8 the lock s default programming from the factory associates certain User Numbers with certain Groups To override these default Group associations Function 35 manua...

Page 20: ...d ends at 2AM on the programmed date Enter 4 1 0 0 0 to disable DST All locks leave the factory with DST enabled and pre programmed to the following start and end dates for the USA beginning 2007 Defa...

Page 21: ...Code Re Lock using Function 46 Programmed Schedules will override the state of the lock when Functions 45 and 46 are used If it is required that programmed schedules do not override Passage Mode enab...

Page 22: ...Code is entered When the Pass Time expires the lock will re lock automatically Use the functions below to change the Pass Time to 3 10 or 15 seconds The Pass Time is defaulted to 3 seconds Pass Time 4...

Page 23: ...abort printing press any key for 3 seconds three short beeps will sound Hold the printer over the lock s infrared sensor as shown in Figure 1 and Figure 2 above For use with DL WINDOWS software refer...

Page 24: ...If the User Code is entered a second time access will be denied and the Event Log will read User Denied Access To use this new feature proceed as follows 1 Enable the Feature Enter Program Mode and e...

Page 25: ...8 0 _ _ _ _ _ Day Time 81 Schedule Disable Group 3 8 1 _ _ _ _ _ Day Time 82 Schedule Disable Group 4 8 2 _ _ _ _ _ Day Time 83 Schedule Disable All Groups 8 3 _ _ _ _ _ Day Time 3 Clear All Schedule...

Page 26: ...riday 9 for Saturday and Sunday and 0 for all days of week Enter time of day in 24 hour format for example for 2 15 PM enter 14 15 Note Use Function 49 to disable Scheduled Passage Mode Scheduled Pass...

Page 27: ...d within this window Group 4 members will be enabled Group 4 members will still need to enter their User Codes to enter For additional information see Group 1 Activated Features on page 28 For day ent...

Page 28: ...dow the User Codes in Group 4 will be enabled If a Group 1 User does not enter their User Code during the specified window Functions 92 93 re main inactive Companies typically use this feature to allo...

Page 29: ...ng any Group 1 member to enable Group 4 Use Function 93 to set the time to close the window 10 00 A M all days of the week Function 92 Open Window Time 8 30 A M Press 9 2 0 0 8 3 0 Function 93 Close W...

Page 30: ...Programming 43 44 Clock Adjust 52 53 54 Pass Time 3 sec 10 sec 15 sec 60 Set Lockout Attempts 61 Set Lockout Time 69 70 Enter Key Enable Disable 0 55 0 0 Seconds 1 9 Attempts 6 1 60 seconds 1 8 Defau...

Page 31: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 32: ...mber 1 2000 User Code 3 6 digits User Name 1 2 3 4 Group Association For a complete list of user codes obtain a printout from either the remote printer Program Function 56 or using the DL WINDOWS Soft...

Page 33: ...nctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in...

Page 34: ...nctions can be programmed For Day Enter 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Monday through Friday 9 Saturday and Sunday 0 All days of the week Enter time of day in...

Page 35: ...and when the lock is first started or when power is removed and re applied see Wiring and Power Up page 11 the original factory default settings are re loaded and take effect DISABLE Turn off DOOR NUM...

Page 36: ...r authorizes any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall ALARM LOCK be liable for...

Reviews: