67. Add System Features
SYSTEM FEATURES
68. Delete All Relay Features added by Function 67.
;
6
8
;
0
0
0
:
•
Aux Relay Features
(12-24. Reserved)
1.
Remote Input switch closed and Function 65
Remote Input
enabled.
Because the Remote Input is enabled by factory default, the Main Relay will
energize when the Remote Input switch is closed. Additionally, if this event (#1)
is then programmed, the Aux Relay will also close for 2 seconds upon closure
of the Remote Input switch.
7.
Scheduled Lock Event.
Aux Relay energizes for 2 seconds when lock is
locked by a Schedule.
2.
Remote Input switch closed and Function 64
Remote Input
disabled.
If
the Remote Input is disabled with Function 64, the Main Relay will NOT ener-
gize when the Remote Input Switch is closed. Additionally, if this event (#2) is
then programmed, the Aux Relay will close for 2 seconds upon closure of the
Remote Input switch. The Main Relay will not energize.
8.
Scheduled Unlock Event.
Aux Relay energizes for 2 seconds when lock is
unlocked by a schedule
3.
Failed attempted entry.
Aux Relay energizes for 2 seconds when an at-
tempted User Code entry via the keypad fails.
9.
Lock Out.
Aux Relay energizes for 2 seconds when a Lock Out occurs (i.e.
number of attempts is exceeded, see Function 60).
4.
Disabled User or Group.
Aux Relay energizes for 2 seconds when a disabled
User or disabled Group member enters a User Code.
10.
Ambush.
Aux Relay energizes for 2 seconds when Ambush is tripped. See
Function 66, page 25.
5.
Follow Main/Entry Relay--Momentary Only.
When the Main/Entry Relay
energizes for any length of time, the Aux Relay energizes for only 2 seconds.
(
Note:
The Aux relay will NOT energize with the Remote Input). Compare with
Event 31.
11.
First Key Press.
Aux Relay energizes for 2 seconds at the first key press of
any sequence.
6.
Group 1 User Code.
Aux Relay energizes for 2 seconds when a scheduled
Group 1 User Code is entered. See Function 90, page 29.
31.
Follow Access Granted--No Time Limit.**
When the Main/Entry relay ener-
gizes for any length of time (such as a valid User Code entered or Remote
Input), the Aux Relay energizes for the
same amount of time as the pro-
grammed Pass Time
. (The Pass Time is the length of time the lock
stays unlocked after a valid User Code is entered. See functions 52-
54). Use this feature for remote monitoring or other activation as this feature
works independently of all other relay options. Programming this feature will
supersede all other programmed relay features. Subsequent relay feature
programming will not take effect while this feature is active. Before program-
ming any other relay features, press
;
6
8
;
0
0
0
:
to delete this feature.
Use Function 67 to program
one or more
lock events and the Aux Relay will energize when the programmed event(s) listed below
occurs. For example, program
;
6
7
;
3
:
and when an attempted entry fails (such as a User who enters
an incorrect or un-programmed User Code), the Aux Relay will energize for 2 seconds.
Note:
For more information about the
Re-
mote Input
, see page 11 (Wiring, Remote Input) and page 25 (Function 65).
4
•
System Options
25. Disable Sounder
26. 5 sec. Delayed Entry *
27. 15 sec. Delayed Entry *
28. 45 sec. Delayed Entry *
•
Remote Input Functions
29.
Toggle Passage Mode.
Remote Input toggles Passage
Mode. Passage Mode enabled = Main/Entry Relay energized.
30.
Forced Unlock Follows Remote Input.
** When Remote
Input activated, the Main/Entry Relay will energize regardless
of its current state.
32.
Remote Input Disables Unit.
**
Regardless of the current
state, that state will remain unchanged (and keypad will be
disabled) for the duration of Remote Input switch closure.
* Features 26, 27 & 28 will delay User Codes 12 and higher only (except 297, 298 and 299).
** Sustained closure of remote input may affect proper audit trail operation.
NOTE:
Enter
;
6
7
;
0
0
0
:
to delete all Relay Features added by Function 67 (identical to Function 68).
•
PC Communication Functions
33. Remote Input Puts Unit in PC Communication Mode
Enter
;
6
8
;
0
0
0
:
to delete all Relay Features added by Function 67.
4
Programming Functions (cont'd)
Ambush Function
1.
Connect relay to a device able to properly monitor dry contacts for an
Ambush
condition.
2.
Program the Relay for
Ambush Tripped
using Program Function 67(10) above.
3.
Set the Ambush Code using Program Function 66.
4.
When the Ambush Code is entered followed by a valid User Code, the relay will close for 2 seconds.
Notes:
The Ambush Code defaults to
99
. An error will sound if you try to program a new User Code starting with the Ambush Code.