
13
TYPICAL APPLICATION: DK3000
Using a normally open push-button switch to provide passage via the door strike, and the Auxiliary Output to trigger a
visual or audible device only when door is unlocked.
Wire nut connections are represented by a
wire with a spherical end, intersecting another
wire, as shown in the
following illustration:
=
+
+
DK3000
Power Input
BL
A
C
K
PURPLE
BLUE
N/C
Com
Entry
Relay
Output
Remote
Release
Output
RE
D
Tamper Output
Mounted to
Housing
Auxiliary
Relay
Output
N/O
GRAY
N/O Push
Button
Switch
WHITE
WHITE
N/C
Alarm
System Zone
Programmed
for 24-Hour
Alarm
BLACK
WHITE
Com
N/O
ORANG
E
Low Voltage
Light
Source/
Sounder
Device
AC/DCV
Light Source/
Sounder
Device Supply
Door
Strike
Door
Strike
Power
Supply
-
-
N/C
POWER SUPPLY OPTIONS
Emergency Exit
Switch
Emergency Exit
Switch
SUPPLY
Simplified Power Supply Option:
Transformer 12 to 24 VAC or DC
Recommended Supply Option:
Battery Backup 12 to 24V AC or DC
WARNING
In all cases, be sure to
allow for emergency exit
during a fire or AC power
failure.
Local jurisdictions may
require use of an access
power supply with battery
backup, with provisions
for timed emergency exit.
Operation
•
The Remote Input is used with a push-button switch
to allow passage.
•
The Auxiliary Relay is used to activate external ser-
vice.
•
Door strike is activated upon a successful code en-
try or push-button closure.
Required Programming
•
Enable Auxiliary Relay follows main Relay (1).
Supplied
Transient
Protection
Summary of Contents for Trilogy DK3000 Series
Page 38: ...38 NOTES ...
Page 39: ...39 NOTES ...