1)

 

Press the STAY button to add a space at the beginning of the zone name. 

2)

 

Press * to move over the “:”. 

3)

 

Press “Chime” to remove the “:” 

4)

 

Press * to move over the digit you want to change. 

5)

 

Press the up or down arrow to change the digit. 

6)

 

Press * to validate the new digit. 

7)

 

Repeat steps 4, 5, and 6 with the other digits. 

8)

 

Press # and EXIT to exit Zone Name Programming Mode. 

 
Within one minute, the HSPA 3G module will update its equipment list 
according to the number of zones you specified. This equipment list will be 
sent with the next phone test or alarm. 
 

Local Zones                                                                             

 

Bit 8, segment 1 of the Zone Type Characteristic Select locations determines 
whether the HSPA 3G module will report alarms for this sensor type (See 
locations 111, 113, ..., 169). 
 
If bit 8 is set, the panel and the module consider this sensor type as “local” 
and will not report an alarm (The alarm will be “reported” locally via the 
siren if so programmed). 
 

Bypassed Zones                                                                      

The HSPA 3G module will report bypass on a zone only when the zone is in 
an “armed” state. The arming level of a zone is determined by 4 bits of 
segment 1 of the Zone Type Characteristic Select locations: 
 

Bit 1:

 Fire zone – Bypass is sent regardless of panel arming state 

Bit 2:

 24 Hour zone – Bypass is sent regardless of panel arming state 

Bit 7:

 Interior zone – Bypass is sent only when panel is armed away 

Bit 8:

 Local zone – Bypass is never sent 

 

Troubleshooting/Testing                                                      

Check the radio status LED 1 to see if it is flashing any errors. See 

Table 5

 on 

page 3 for descriptions of the errors indicated. 
 
Check radio status LED 4 for signal strength (if it is toggling on and off it is 
connected). If signal strength is less than 2, do a walking signal strength test 
(see 

Module Location Guidelines

 on page 1). 

 
If touchpads/sirens are beeping even though the system is not armed, press 
* 2 to display the trouble condition. Refer to specific touchpad manual for 
more details. 
 

Account Creation                                                                  

 

Before installing the Alarm.com HSPA 3G Module in a NetworX system, a 
new customer account needs to be created with Alarm.com. We recommend 
creating the account at least 24 hours in advance of installation to ensure 
that the radio is activated prior to installation. 
 
To activate an account go to www.alarm.com/dealer and login.  Under the 
“Customers” heading at the top left of the page click on “Create New 
Customer”. You will need the following customer information to create the 
account: 

 

Customer Name 

 

Customer Address 

 

Customer Phone Number 

 

Customer E-mail 

 

Preferred login name for the customer 

 

Alarm.com Module Serial Number 

 
At the end of the account creation process you will be able to print a 
Welcome Letter for the customer that has their login information and 
temporary password for the Alarm.com website. 
 

FCC Compliance                                                                     

  

Changes or modifications not expressly approved by Alarm.com can void the 
user’s authority to operate the equipment. 
 
This equipment has been tested and found to comply with the limits for a 
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 
 

• Reorient or relocate the receiving antenna. 
• Increase the separation between the equipment and receiver. 
• Connect the equipment in to an outlet on a circuit different from 
that which the receiver is connected. 
• Consult the dealer or an experienced radio/TV technician for help. 
 

This equipment complies with the FCC RF radiation exposure limits set forth 
for an uncontrolled environment. This equipment should be installed and 
operated with a minimum distance of 20 centimeters between the radiator 
and your body. 
 
Under Industry Canada regulations, this radio transmitter may only operate 
using an antenna of a type and maximum (or lesser) gain approved for the 
transmitter by Industry Canada. To reduce potential radio interference to 
other users, the antenna type and its gain should be so chosen that the 
equivalent isotropically radiated power (e.i.r.p.) is not more than that 
necessary for successful communication. 
Conformément à la réglementation d'Industrie Canada, le présent émetteur 
radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou 
inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de 
réduire les risques de brouillage radioélectrique à l'intention des autres 
utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la 
puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité 
nécessaire à l'établissement d'une communication satisfaisante. 
 
This device complies with Industry Canada license-exempt RSS standard(s).  
Operation is subject to the following two conditions: (1) this device may not 
cause interference, and (2) this device must accept any interference, 
including interference that may cause undesired operation of the device. 
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux 
appareils radio exempts de licence. L'exploitation est autorisée aux deux 
conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) 
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, 
même si le brouillage est susceptible d'en compromettre le fonctionnement. 
 
FCC ID: YL6-143200H5V4, IC: 9111A-143200H5V4 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Reviews: