Radio Status LEDs                                                                  

There are five small radio status LEDs, located on the bottom of the module 
(see 

Figure 1

). 

Table 4

 below describes the LED functions. 

 
Table 4: LED Functions 

LED 

Function 

L1 

Error LED. Flashes 1 to 8 times in an 8-second interval to indicate 
specific error. See 

Table 5

Error! Bookmark not defined.

 for errors 

and common fixes. 

L2 

Panel Communication and Z-Wave status messages. Flashes every 
time the module communicates with the panel and flashes in 
patterns to indicate Z-Wave status. 

L3 

HSPA Communication. Flashes every time the HSPA signal level is 
checked and when packets are exchanged with Alarm.com. 

L4 

HSPA Signal Level. Flashes 0 to 5 times to indicate signal strength, or 
toggles on/off slowly when communicating with Alarm.com servers. 

L5 

Z-Wave Error LED. See 

Table 6 

for error descriptions. 

 
LED Details 

LED L1 (red) 

L1 flashes when there is an error. The number of flashes indicates the error 
number. If there are two or more errors at the same time, the errors will 
flash one after the other. The LED will stay off for at least four seconds 
between errors. 

Table 5: Errors flashed on L1 (red)

 

Number of 
flashes 

Error and solution 

Module cannot communicate with the panel.  Perform a power 
cycle on the panel. If the error persists lift the module out of 
the panel and re-insert it. If the error is still observed try a 
different module. Finally, if that does not fix the problem try a 
different panel. 

The SIM card is missing. The SIM card holder can be found on 
the module.  Verify that the SIM card holder is closed securely 
and that there is a SIM card in the holder.   

The module is trying to register on the HSPA network. If it 
persists for more than a few minutes, the module is having 
problems registering with the HSPA network. Check L4 for 
signal level. If signal level is lower than 2 “bars”, change the 
panel’s location or use a remote antenna option. If the signal is 
good, the module may be roaming on a HSPA network that 
does not partner with our HSPA providers, or the SIM card was 
not activated yet because the Alarm.com account was not 
created correctly. 

The module is registered on the HSPA network but cannot 
connect with Alarm.com. Contact Alarm.com Technical 
Support. 

Radio portion of the module is not working correctly. If this 
persists for more than a few minutes the module may need to 
be replaced.  This error is extremely rare so verify that the 
module is flashing 5 times.   

This is an error only if it persists for more than a minute. 
Otherwise, it’s just an indication that the module is fixing an 
unusual condition regarding communication with the HSPA 
network. 

There are bit sets in Location 21 that prevent Alarm.com from 
getting the sensor list from the panel. In Location 21, segment 
1 if bits 5 and 6 are set the module can not retrieve the sensor 
list. Note that bit 7 will prevent location 21 from being isplayed 
at the keypad. Bits 5, 6 and 7 can only be set via the 
Downloader program. 

This could also mean that the module is not compatible with 
the current panel type. 

If it persists, the account may have been set up incorrectly.  
Contact Alarm.com Technical Support. You will be asked to 
check the serial number of the module. 

LED L2 (yellow) 

L2 flashes with every communication between the module and the panel. 
Normal pattern calls for a series of quick flashes every two seconds in Idle  
Mode or four seconds in PowerSave Mode. It also occasionally flashes in 
patterns to indicate Z-Wave status. See the 

Table 6

 below for a description of 

various possibilities. 

Table 6: Z-wave LED status indicators 

LED 2 

LED 5 

Device status or error 

Description 

4-blink 

 

Add Mode (lasts 120 
seconds or until a device 
is added) 

In this mode you can add a 
device to the local Z-Wave 
network. Devices cannot be 
added to a network if they 
are already a part of a 
network 

2-blink 

 

Delete Mode (lasts 120 
seconds or until a device 
is deleted) 

In this mode you can delete a 
device from a Z-Wave 
network. A device can only 
be in one network at a time, 
and must receive a “delete” 
command before it can be 
learned into a new network 

Solid 

 

Successful add 
node/remove 
node/replication (lasts 
60 seconds) 

After receiving this signal 
leave all devices by the HSPA 
module for 1 minute. Locks 
must be left next to the 
module for 4 minutes 

Solid 
with 
one 
blink 

 

Add node attempt failed 
because node already in 
network (lasts 60 
seconds) 

Device you attempted to add 
to a network is already in a 
network, and must be 
“deleted” before it can join a 
new network 

 

2-blink 

No other nodes are in 
the network (lasts until a 
device is added to the 
network) 

No devices have been added 
that can be controlled by the 
HSPA module yet. See above 
for instructions on how to 
add devices 

 

5-blink 

Learn mode error (lasts 
60 seconds) 

The device was not 
successfully added to the Z-
Wave network. 

 

6-blink 

No Home ID present 
(lasts until the module 
connects to Alarm.com 
and is configured) 

When the HSPA module first 
connects to Alarm.com it is 
configured with a necessary 
unique network ID 

LED L3 (yellow) 

L3 flashes with every communication between the module and its radio unit 
in Idle Mode, and with every communication with Alarm.com in Connected 
Mode. In PowerSave Mode, this LED flashes in unison with LED 2. 