Concord 4 CDMA Module

 

|

 

Installation Guide 

 

6-blink 

No Home ID 
present (lasts 
until the module 
connects to 
Alarm.com and is 
configured) 

When the CDMA module first connects 
to Alarm.com it is configured with a 
necessary unique network ID. 

 

Module States (modes)                                                       

 

There are three module states (modes). 
 

Idle  

In Idle mode, the AC power is up, the battery level is greater than 11.5 
volts, and the module is not currently connected to the Alarm.com 
servers. This is normal for the module and the most common state. 
 

L1

 - Flashes errors, if any. 

L2 

- Communication with panel 

L3 

- Communication with radio unit 

L4

 - Signal level (0 to 5 bars) 

L5

 – Flashes errors, if any 

 

PowerSave mode 

In PowerSave mode, the module just powered up, AC power is down, or 
battery level is less than 11.5 volts. The radio part of the module draws 
10 mA in PowerSave mode. It is fully functional and will go into 
Connected mode as soon as a signal needs to be sent. Performing a 
manual phone test will switch the module into Idle mode and update the 
signal level reading. 
 

L1

 - Inactive 

L2

 - Communication with panel 

L3

 - Same flashing pattern as L2 

L4

 - Inactive 

L5

 – Inactive 

 

Connected mode 

In Connected mode, the module is connected to the Alarm.com servers 
and reported an alarm or other condition. The module stays in 
Connected mode for at least six minutes after the last message is 
exchanged. Entering Installer Programming mode will cause the module 
to go into Idle mode. 
 

L1 

- Flashes errors, if any 

L2 

- Communication with panel 

L3 

- Communication with Alarm.com 

L4

 - Alternates two seconds on, then two seconds off 

L5

 - Inactive 

 

Troubleshooting/Testing                                                      

Tips 

 

Check CDMA status LED L1 to see if it is flashing any errors. See 

Table 5 

on page 4 for descriptions of the errors indicated. 

 

If the power LEDs (the green LED at the top of the module in 

 

Figure 1 

on page 1) is not on, turn off the panel power and verify 

that all wiring is correct. 

 

If the Module status LEDs (

on the left side of the module in 

 

Figure 1 

on page 1

) do not turn on immediately after initial power 

up, be sure you have given enough time for the module to initiate 
communication with Alarm.com

.  

You must wait 5 to 8 minutes 

after power up for the module to communicate with Alarm.com. 
Verify that the “Access Code Lock” feature (in panel memory) is 
turned off.  “Access Code Lock” 

MUST

 be turned off for correct 

operation. 

 
Sensors 94, 95, 96                                                                 

  

If sensors 94, 95, and 96 are not learned in, after doing a manual 
phone test, the text for these sensors will display important 
information for troubleshooting purposes.  Alarm.com Technical 
Support staff may request this information during service calls. 

 

Sensor 94 text:  

IMSI number. 

 

Sensor 95 text:  

Type of central station reports enabled.   

See 

Table 7 

for a reference of the codes displayed. 

 

Sensor 96 text:  

Module serial number. 

 

Table 7: Central Station Reporting Bits 

Phone Test 

Panel programming 

Alarms 

Tamper 

System trouble 

Cancels 

Sensor trouble 

Normal activity 

Arming/disarming 

Modem on line 

Sensor bypass 

Pings 

AC power failure 

Panel low battery 

Phone failure (phone failure will always be reported for alarms and cancels) 

 

Specifications                                                                         

  

Compatibility 

Concord panels  with software versions  4.0 and  higher 

Power 
requirements 

12 V nominal, 65 mA (continuous) 1600 mA 
(instantaneous peaks) maximum (from panel or auxiliary 
power supply) 

Cellular network 

1xRTT  

Power/data bus 

One 4-wire SuperBus 2000 auto addressing power 
communication data bus 

Indicators 

One module/panel communication status LED, one 
module power LED, one automation LED, three wireless 
communication status LEDs 

Operating 
Temperature 

32 to 120°F (0 to 49°C) 

Storage 
Temperature 

-30 to 140°F (-34 to 60°C) 

Humidity 

90% relative humidity non-condensing 

Case color 

Belgian gray 

Case material 

High-impact, ABS plastic 

Listings 

FCC part 15, Verizon Certified 

 

Regulatory Information                                                                                   

 

Changes or modifications not expressly approved by Alarm.com can void the user’s authority 
to operate the equipment.  
  
This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures:  

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver.  

 

Connect the equipment into an outlet on a circuit different form that which the 
receiver is connected  

 

Consult the dealer or an experienced radio/TV technician for help.  

Operation is subject to the following two conditions:  
(1) This device may not cause interference  
(2) This device must accept any interference, including interference that may cause undesired 
operation of the device  
  
This equipment complies with the FCC RF radiation exposure limits set forth for an 
uncontrolled environment. This equipment should be installed and operated with a minimum 
distance of 20 centimeters between the radiator and your body.  
  
FCC IDs: YL6-143200H5V4  
 
This device contains FCC ID: RI7CE910-DUAL, IC: 5131A-CE910-DUAL  