Alarm.Com ADC-FLEX-100 Installation Manual Download Page 2

How will this Alarm.com Flex IO™
sensor be used?

Description

Installation guide

Contact Sensor

using built-in reed

switch

Selecting

Contact Sensor

allows you

to use the Flex and built-in reed
switch to monitor if something is
opened or closed.

Using the Alarm.com Flex IO™
sensor as a contact (built-in
reed switch)

Wired Contact Sensor

using wired

loop input

Selecting

Wired Contact Sensor

allows you to wire a contact sensor
to the Flex using the loop input
terminal.

Alarm.com Flex IO™ sensor -
Wired Contact (Loop Input)
Installation Guide

Pull-Apart Sensor

using pull-apart

or Magnapull sensor

Selecting

Wired Contact Sensor

allows you to use the Flex with a
pull-apart or Magnapull sensor. This
could be used to determine if
something is moved from its
location.

Alarm.com Flex IO™ sensor -
Pull-Apart Installation Guide

Gate control

using a compatible

gate controller

Selecting

Gate Control & Contact

Sensor

or

Gate Control & Wired

Contact

allows you to use the Flex

with a compatible gate controller.
This allows you to monitor and open
the connected gate controller.

Alarm.com Flex IO™ sensor -
Ghost Controls TSS1
Installation Guide

Alarm.com Flex IO™ sensor -
LiftMaster LA400/500
Installation Guide

Alarm.com Flex IO™ sensor -
Mighty Mule MM371W
Installation Guide

For more information about use cases, see

Alarm.com Flex IO™ sensor - Supported Use Cases

.

Expand all

Equipment

In the box:

• Alarm.com Flex IO™ sensor

• Magnet

• 4x AA 1.5V lithium batteries

• Installation guide

• 300 kΩ resistor (optional)

Recommended tools and supplies (not included):

https://answers.alarm.com/Partner/Installation_and_Troubleshooting/Cellular_Sensors/Alarm.com_Flex_IO%E2%84%A2_sen…

Updated: Mon, 10 Oct 2022 23:21:36 GMT

2

Summary of Contents for ADC-FLEX-100

Page 1: ...ing compatible devices that lack long range connectivity Important The Alarm com Flex IO sensor is a monitoring device that is not intended for life safety use cases For a video guide about installing...

Page 2: ...moved from its location Alarm com Flex IO sensor Pull Apart Installation Guide Gate control using a compatible gate controller Selecting Gate Control Contact Sensor or Gate Control Wired Contact allow...

Page 3: ...put tools and supplies if required not included 18 22 AWG wire Power supply ADC FLEX 100 PS Wire retention clip ADC FLEX 100 WRC Step 1 Determine location Before installing your device it is important...

Page 4: ...re available Only one reed switch position can be active at a time You will select the reed switch position in Step 2 Use the tick marks on the sides of the device for guidance Position 1 Position 2 P...

Page 5: ...ed flush to the install surface Important A mounting tamper is located on the back of the Alarm com Flex IO sensor This tamper button must be fully pressed until you hear a clicking sound to avoid rep...

Page 6: ...ions Anything from 6 15VDC is acceptable A minimum of 1 Amperage is required For best performance 18 22 AWG wire should be used Important DC power is required for relay installations due to increased...

Page 7: ...de is initiated the LED will display the cell signal strength in a continuous loop for 2 minutes based on the patterns below It may take up to 30 seconds for the signal strength to be acquired As you...

Page 8: ...ast one Alarm com Flex IO sensor has been added to their Service Package The Alarm com Flex IO sensor is listed under Cellular Sensors 4 Click Equipment 5 Click Cellular Sensors 6 Click Add a Cellular...

Page 9: ...any devices into the screw terminals it is recommended to do so before mounting the Alarm com Flex IO sensor https answers alarm com Partner Installation_and_Troubleshooting Cellular_Sensors Alarm co...

Page 10: ...to over torque the screws Power tools should be avoided If pilot holes are necessary a drill bit size of 5 64 is recommended Using zip ties Zip ties should have a maximum width of 0 34 inches UV resi...

Page 11: ...e the battery door screw is securely tightened until the door tamper is no longer detected and then add an additional turn to the screw This will also ensure a waterproof seal If this screw is not ful...

Page 12: ...d blinking twice when the device is tripped If the device is not communicating with Alarm com see Advanced Troubleshooting Using MobileTech For more information on LED patterns see Alarm com Flex IO s...

Page 13: ...d only for control lines dry contact Caution Can never be connected directly to control electrical loads This will damage the device Dimensions Main unit 6 8 x 2 2 x 1 3 17 3 x 5 6 x 3 3 cm Magnet 3 1...

Page 14: ...or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Co...

Reviews: