45
4 Functions during the Dive
III Uwatec
®
Aladin
®
Air Z
III
4.6 Tank pressure (only with transmitter)
Tank pressure is indicated in the lower display.
The tank pressure transmitted to the computer by the transmitter
is also used for the calculation of the remaining bottom time (RBT)
and the work load.
Messages: In case of increased air consumption, Aladin
®
Air Z displays a
lung symbol in the lower display and an acoustic alarm occurs.
Response: In order to prevent additional saturation, reduce exertion and
breathe more slowly.
Interruption of transmission: If no data are received, the display of Aladin
®
Air
Z shows the interruption of the transmission (antenna warning, alarm signal)
30 seconds after the last transmission. Without a transmission of sensible data
in the following 40 seconds <—> appears instead of the tank pressure and the
RBT (remaining bottom time) is no longer displayed (alarm signal). In this case,
either transmitter or receiver do not work properly or the position of dive com-
puter and transmitter is improper. As soon as data are transmitted again, the
computer restarts to display tank pressure and RBT.
tank data
psi
tank data
psi
tank data
psi
tank data
WARNING
Summary of Contents for ALADIN AIR Z