Installation
akYtec GmbH · Vahrenwalder Str. 269 A · 30179 Hannover · Germany · Tel.: +49 (0) 511 16 59 672-0 · www.akytec.de
5
4 Installation
To mount the device, cut out two holes Ø22.5 mm and Ø4 mm in the panel, as shown in Fig. 4.2.
Carefully position the supplied gasket on the device rear surface. Insert the cylindrical body of the
device into the borehole and tighten the nut from the rear side of the panel (Fig. 4.3).
Fig. 4.1 Dimensions
Fig. 4.2 Panel cutouts (front view)
Fig. 4.3 Mounting
The safety precautions from the section 4.1 and the operating conditions from the section 2.1 must
be observed.
4.1
Safety precautions
DANGER
Ensure that the mains voltage matches the voltage marked on the nameplate!
Ensure that the device is provided with its own power supply line and electric fuse!
►
NOTICE
Switch off the power supply before working on the device. Switch on the power
supply only after completing the work.
EMC safety:
−
Signal cables should be routed separately or screened from the supply cables.
−
Shielded cable should be used for the signal lines.
−
Connect the screen in the electrical cabinet in accordance with EMC requirements.
4.2
Wiring
Wire the detachable part of the included 4-pole terminal block according to Fig. 4.4 and connect it
to the built-in part of the block on the rear side of the device.
ALT
100
60
35
60
SEL
OK
ESC
22,5
51
100
60
31
Switch panel
Gasket
Nut
Enclosure