Fig. 5.4   NPN transistor output 

6  Operation 

After the device is powered on the operating mode is activated. The type of the signal can be 
selected in the parameter 

in.t

 “Input signal”. The complete list of the programming 

parameters is shown in Table 7.2. 

The input signal is digitalised, the square root calculated (if the function is enabled), the 
signal scaled and displayed. The scale factor is calculated based on the parameter 

di.Lo

 

“Lower measuring limit” and 

di.Hi

 “Upper measuring limit”. The display decimal point can be 

specified in the parameters 

di.P

For other signal processing functions see sections 6.1…6.3. For displayed errors see Table 
6.1. 

6.1 

Control

 

ON/OFF control is implemented with the NPN transistor output (see 5.1.2). The parameters 

SP.Lo

 “Lower setpoint limit” and 

SP.Hi

 “Upper setpoint limit” specify the control limits. The 

control function can be selected in the parameter 

Cnt

 

Heating 

 

Cooling 

 

Alarm within limits 

 

Alarm outside limits 

The safe output state can be selected in the parameter 

out.E

 

Fig. 6.1 

DO-

K

_U

U

+

VD

DO+

Summary of Contents for ITP14

Page 1: ...ahrenwalder Str 269 A 30179 Hannover Germany Tel 49 0 511 16 59 672 0 www akytec de ITP14 Universal process indicator User guide ITP14_2018 03_0272_EN All rights reserved Subject to technical changes...

Page 2: ...ations 2 2 1 Environmental conditions 2 3 Intended use 3 4 Functions 3 5 Installation 3 5 1 Wiring 3 5 1 1 Input 4 5 1 2 Output 4 6 Operation 5 6 1 Control 5 6 2 Alarm 6 6 3 Filter 6 6 4 Square root f...

Page 3: ...put resistance 0 5 mA 0 4 20 mA 120 ohm 0 2 10 V 250 kohm Output 1 Type NPN transistor Loading capacity 200 mA 42 V DC Enclosure for panel mounting Dimensions 48 x 26 x 65 mm Weight approx 30 g Table...

Page 4: ...mode see 7 The function buttons are positioned on the rear part of the device Main functions Analog input 0 5 mA 0 4 20 mA 0 2 10 V Measuring and displaying of a process value Signal scaling Adjustabl...

Page 5: ...rovided with its own power supply line and electric fuse I 0 5 A The maximum conductor cross section is 1 mm Wires should be stripped for approx 8 10 mm 5 1 1 Input Fig 5 2 Current sensor wiring Fig 5...

Page 6: ...yed The scale factor is calculated based on the parameter di Lo Lower measuring limit and di Hi Upper measuring limit The display decimal point can be specified in the parameters di P For other signal...

Page 7: ...ut signal and the lower the susceptibility to interference is The filter is deactivated if td 0 Fig 6 2 Filter time constant 6 4 Square root function The function is intended for transmitters with the...

Page 8: ...tion while changing parameter if no button was pressed within 20 s the device returns to the operating mode automatically Table 7 2 Programming parameters Name Display Parameter Valid value Descriptio...

Page 9: ...Default d Fn d Fn Alarm function ON OFF OFF Table 7 3 Service menu Display Comments Valid values ES Restore factory settings 0 User settings 1 Factory settings CLb Service function SoFt Firmware vers...

Page 10: ...mage The device should be cleaned with a damp cloth only No abrasives or solvent containing cleaners may be used 9 Transportation and storage Pack the device in such a way as to protect it reliably ag...

Reviews: