3  Specifications 

Table 3.1   Specifications

 

Power supply 

24 (8…30) V DC 

Input signal 

5…400 V AC, (50±25%) Hz 

Inputs 

Power consumption, max. 

4 W 

Input resistance, min. 

500 kohm 

Accuracy 

0.25% + 1 digit 

Display 

LED, 4 digits, 7 segment 

Character height 

14 mm 

Display color 

red 

Sampling rate 

1 reading / s 

IP Code 

front IP65, rear IP20 

Dimensions 

48 x 26 x 65 mm 

Weight 

approx. 30 g 

Protection class 

II 

Ambient temperature 

-20…+50 °C 

Storage temperature 

-25…+55 °C 

Humidity 

up 80% at 35°C (non-condensing) 

4  Description 

A 4-digit, 7-segment LED display (red) with 14 mm character height is located on the front of 
the device for displaying the measured values and error messages. The terminals are 
located on the rear side of the device. The maximum wire size is 0.75 mm

2

 

 

Fig. 4.1 

Fig. 4.2 

 

5  Installation 

The device is designed for switch panel mounting in a borehole of Ø22.5 mm (see Annex A 
for dimensional drawings). 
Carefully position the supplied gasket on the display rear surface. Insert the cylindrical part 
of the device into the borehole and tighten the nut from the rear side of the switch panel. 

Summary of Contents for INS-F1

Page 1: ...mbH Vahrenwalder Str 269 A 30179 Hannover Germany Tel 49 0 511 16 59 672 0 www akytec de INS F1 Digital Voltmeter User guide INS F1_2017 10_0264_EN All rights reserved Subject to technical changes and misprints ...

Page 2: ... akytec de 1 Contents 1 Safety guidelines 2 1 1 Definitions 2 1 2 General instructions 2 2 Intended use 2 3 Specifications 3 4 Description 3 5 Installation 3 6 Electrical wiring 4 7 Operation 4 8 Maintenance 4 9 Transportation and storage 5 10 Scope of delivery 5 Appendix A Dimensions 5 ...

Page 3: ...ary power is switched off the unit terminals can carry dangerous voltage Switch off the auxiliary voltage and the measured voltage when working on the device WARNING Improper use Improper use of the device can cause personal injury property or environmental damage Follow the maintenance instructions and use only original spare parts from the manufacturer The manufacturer shall not be liable for cl...

Page 4: ...mbient temperature 20 50 C Storage temperature 25 55 C Humidity up 80 at 35 C non condensing 4 Description A 4 digit 7 segment LED display red with 14 mm character height is located on the front of the device for displaying the measured values and error messages The terminals are located on the rear side of the device The maximum wire size is 0 75 mm2 Fig 4 1 Fig 4 2 5 Installation The device is d...

Page 5: ...ing to Fig 3 to the device The maximum wire size is 0 75 mm Fig 6 1 7 Operation After the power supply is switched on the following values will be displayed successively Firmware checksum 8 digits ticker tape Firmware version Ux xx Measuring voltage If the measuring voltage is less than 5 V the error message 0000 will be displayed If the measuring voltage is greater than 400 V the error message HH...

Page 6: ...livery into operation it must be carefully stored at a protected location The device should not be stored in an atmosphere with chemically active substances Permitted storage temperature 25 55 C NOTICE The device may have been damaged during transportation Check the device for transport damage and completeness Report the transport damage immediately to the shipper and akYtec GmbH 10 Scope of deliv...

Reviews: