1  Safety guidelines 

1.1 

Definitions 

 

DANGER 

DANGER indicates an imminently hazardous situation which, if not avoided, will 
result in death or serious injury.

 

 

 

 

 

WARNING 

WARNING indicates a potentially hazardous situation which, if not avoided, could 
result in death or serious injury.

 

 

 

 

 

CAUTION 

CAUTION indicates a potentially hazardous situation which, if not avoided, could 
result in minor or moderate injury.

 

 

 

 

 

NOTICE 

NOTICE indicates a potentially harmful situation which, if not avoided, may result 
in damage of the product itself or of adjacent objects.

 

1.2 

General instructions 

 

DANGER 

Dangerous voltage 
Electric shock currents could kill or seriously injure. 
All electrical connections must be performed by a fully qualified electrician. 
Ensure that the mains voltage matches the voltage marked on the nameplate! 
Ensure that the device is provided with its own power supply line and electric 
fuse! 
Even when the auxiliary power is switched off the unit terminals can carry 
dangerous voltage! Switch off the auxiliary voltage and the measured voltage 
when working on the device!

 

 

 

 

 

WARNING 

Improper use 

Improper use of the device can cause personal injury, property or environmental damage. 
Follow the maintenance instructions and use only original spare parts from the 
manufacturer! 
The manufacturer shall not be liable for claims of any type based on operation contrary to 
the intended use! 

 

 

 

 

CAUTION 

Improper installation 

Improper installation can cause serious or minor injuries and damage the device. 
Installation must be performed only by fully qualified personnel. 

2  Intended use 

The INS-F1 is a digital voltmeter for measuring effective voltage from 5 to 400 V AC. The 
device requires 24 V DC auxiliary voltage. It is designed for use in industrial applications. 

The device may only be operated 

– 

properly installed and 

– 

in accordance with the specifications. 

Improper use 

– 

The device should not be used for medical devices which receive, control or otherwise 
affect human life or physical health. 

– 

The device should not be used in an explosive environment. 

– 

The device should not be used in an atmosphere with chemi-cally active substance. 

 

 

 

 

 

 

Summary of Contents for INS-F1

Page 1: ...mbH Vahrenwalder Str 269 A 30179 Hannover Germany Tel 49 0 511 16 59 672 0 www akytec de INS F1 Digital Voltmeter User guide INS F1_2017 10_0264_EN All rights reserved Subject to technical changes and misprints ...

Page 2: ... akytec de 1 Contents 1 Safety guidelines 2 1 1 Definitions 2 1 2 General instructions 2 2 Intended use 2 3 Specifications 3 4 Description 3 5 Installation 3 6 Electrical wiring 4 7 Operation 4 8 Maintenance 4 9 Transportation and storage 5 10 Scope of delivery 5 Appendix A Dimensions 5 ...

Page 3: ...ary power is switched off the unit terminals can carry dangerous voltage Switch off the auxiliary voltage and the measured voltage when working on the device WARNING Improper use Improper use of the device can cause personal injury property or environmental damage Follow the maintenance instructions and use only original spare parts from the manufacturer The manufacturer shall not be liable for cl...

Page 4: ...mbient temperature 20 50 C Storage temperature 25 55 C Humidity up 80 at 35 C non condensing 4 Description A 4 digit 7 segment LED display red with 14 mm character height is located on the front of the device for displaying the measured values and error messages The terminals are located on the rear side of the device The maximum wire size is 0 75 mm2 Fig 4 1 Fig 4 2 5 Installation The device is d...

Page 5: ...ing to Fig 3 to the device The maximum wire size is 0 75 mm Fig 6 1 7 Operation After the power supply is switched on the following values will be displayed successively Firmware checksum 8 digits ticker tape Firmware version Ux xx Measuring voltage If the measuring voltage is less than 5 V the error message 0000 will be displayed If the measuring voltage is greater than 400 V the error message HH...

Page 6: ...livery into operation it must be carefully stored at a protected location The device should not be stored in an atmosphere with chemically active substances Permitted storage temperature 25 55 C NOTICE The device may have been damaged during transportation Check the device for transport damage and completeness Report the transport damage immediately to the shipper and akYtec GmbH 10 Scope of deliv...

Reviews: