User Troubleshooting
8
User Troubleshooting
If the shower does not work as expected, switch off at the pull-cord or isolating switch,
wait 30 minutes for the shower to reset then switch back on again.
Fault
Cause
Remedy
No Water Flow
Shower runs hot
and cold during use
Water from
pressure relief
outlet-PRD
activated
Fault LED’s Display
(See Page 32 for
reference)
Water isolating valve in off position
Filter blocked
Power supply not on
Obstruction in hose or handset
Low Flow/Low Pressure
Inlet Thermistor Fault
Outlet Thermistor Fault
Uncontrolled over Temperature
Insufficient water flowing
through the shower
Water pressure is below minimum
requirement. This may be caused
by other appliances on the same
pipework drawing water
Call AKW Technical Enquiries
Call a qualified service
engineer and refer to Page 32
Clean the handset
Increase the flow by adjusting
the temperature control knob
to cooler setting.
Reduce the power setting
Water temperature
too hot
Check running pressure
(minimum of 0.5bar)
(1bar Recommended)
Wait until pressure increases
Turn on water supply
Turn off water supply, remove
filter and clean
Turn on power supply