DoorNum
in the HTTP command above refers to the relay number #1 to be
triggered for the door access.
Parameter Set-up:
•
Enabled:
enable the HTTP command to unlock the function by going to
Enable
.
•
Username:
enter the user name of the device web interface, forexample,
Admin
.
•
Password
: enter the password for the HTTP command. For example,
12345
.
Please refer to the following example:
http://192.168.35.127/fcgi/do?
action=OpenDoor&UserName=admin&Password=12345&DoorNum=1