![Akuvox C313W-2 Manual Download Page 79](http://html.mh-extra.com/html/akuvox/c313w-2/c313w-2_manual_2887385079.webp)
C313W-2
Indoor Monitor Administrator Guide
AKUVOX SMART INTERCOM www.akuvox.com
71
SIP Message
: enable SIP message if you want the SIP message to be
sent to a designated SIP account as an action
Call
: enable Call if you want you a call to go to a designated SIP or IP
number.
Local relay:
enable local relay if you want to trigger local relay as an
action.
13.2.7.2. Configure Alarm Action via HTTP Command
To set up the HTTP Command action, you can click “
Enable
” in the
Send
HTTP
field to enable the actions for the alarm sensor installed in different
locations. Then enter the HTTP command provided by the manufacturer of
the device on which the action is to be carried.