Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
Email: [email protected]
Make sure that the venturi nozzle is never fed dry with ozone / air, but establish a water flow through the venturi
line, otherwise the venturi nozzle could be damaged and the ozone generator cannot discharge the ozone either !
Do not switch the ozone generator on/off in short intervals, but always wait approx. 5 minutes before switching it on
again.
2. During operation
Make sure that you and third parties are not exposed to ozone gas. If you notice an ozone smell during operation of
the unit, please switch off the ozone unit immediately and check the pipes and the proper functioning of the unit.
3. After completion of ozonisation
First check whether the unit is also no longer producing ozone, switch it off completely and if it is in off mode for a
longer period of time, please pull the mains plug.
Please note that ozone has a half-life of approx. 20 minutes. If ozone has been added to the air indirectly via the
water, we also
recommend that you do not enter this area for approx. 30 - 45 minutes after ozonisation has ended !
If room air has been ozonised directly or indirectly, make sure that the room/object is sufficiently ventilated with
fresh air from outside. In this context, we recommend that you ventilate the room for approx. 20 minutes before
people or animals enter the room again!
If the ozonised room cannot be ventilated with fresh air from outside (e.g. due to its construction) and the ozone
treatment phase lasted longer than 80 minutes, we recommend that humans and animals do not stay in this room
for approx. 60 minutes. In case of a room air ozonisation longer than 400 minutes, we recommend no stay of
humans and animals in this room for the duration of approx. 2 hours.
4. Cleaning
Only clean the housing !
Please disconnect the mains plug before cleaning the water-ozone generator.
Only use mild cleaning agents to clean your water-ozone generator.
NEVER spray your water ozone generator (e.g. with water or similar).
Technical data
Model designation:
WDH-WP15
Voltage:
220-240V ~ 50Hz
Maximum power consumption:
80 W (0.4 A)
Ozone output (optimal):
1,500 mg/h (1.5 g/h)
Max. Ozone concentration:
15-20 mg/l
Max. Outlet pressure:
10 PSI
Waterproofness:
IPx0
Dimension (H/W/D):
240 x 180 x 420 mm
Weight:
5.6 kg
Application range:
5°C - 40°C