5.) Setting the various operating modes (functions) 
 

Press the Settings button          in succession for the desired setting: 

 

 

 
 
 
 
 
 
 

 

Furthermore, combinations can be set that enable joint operation of the individual functions ! 
 

6.) Activate the automatic air sensor 
 

Press the Auto button         on your air purifier. The air sensor thus switches on and automatically starts measuring 
the air quality. There are 4 possible results of the determined air quality (see diagram below): 

 

Please note that the proper air sensor function is only available after approx. 3 minutes ! 

 

 

 
 

 

No bar (

PM-value 0-30

)  

=    Very good air quality 

>     Air circulation extremely low

 

 
 

 

3 bars (

PM-value 30-75

=    Light air pollution 

 

>     Air circulation jumps to level 1 (weak) 

 

 

 

6 bars (

PM-value 75-150

=    Average air quality   

>     Air circulation jumps to level 2 (medium) 

 

 

 

9 bars (

PM-value over 150

=    Bad air quality 

 

>     Air circulation jumps to level 3 (strong) 

 
In addition to the air quality display shown above, you will also see a PM value in the display. You can read at the 
top which air quality category the respective PM value falls into. 
 
Note: The air sensor is located at the front right behind the filter flap and reacts mainly to odors and slightly to 
particles in the air and thus always gives only a tendency of the air quality. Since it is a tendency (similar to a 
weather station), this function cannot provide a 100% reliable statement about pollutants in the room air or about 
the entire area of a room. 
 
From a humidity of approx. 80% r.l. upwards, the air sensor probe may malfunction. In this case, we ask you to 
dispense with the air sensor function (Auto). 
 
Furthermore, stronger operating fluctuations may occur from time to time, as the air sensor probe is exposed to the 
air draught. 
 
 

This function generates more than 5 million anions per second, which proactively 
combat smoke and other particles in the room. 

Eliminates many of the most common types of bacteria and viruses. Furthermore, 
the UV light ensures that the filters themselves can never become a breeding 
ground for germs ! (There is a 6W UV lamp installed behind the filters). 

Air quality display 

Summary of Contents for WDH-C03

Page 1: ...ps In case of any problems We hope the device meets your expectations If despite the greatest possible care there should ever be cause for complaint we ask you to contact us briefly because we are ver...

Page 2: ...articles in the room Airquality sensor optionally switchable Automatically measures the air quality If the determined air quality is good the air purifier automatically turns OFF If the result is oppo...

Page 3: ...he recommended voltage for the operation of the device Make sure that the power cord is unfolded untied before connecting it to the power Make sure that the plug is clean and properly connected to the...

Page 4: ...ntrol receiver 6 Filter change indicator 2 Signal lamp anion function 7 Operating keys air sensor air circulation 3 Signal lamp UV light function Timer Operating Mode Reset 4 Display of the current te...

Page 5: ...ilter compartment diagram 1 Filter flap 2 Prefilter 3 HEPA Filter 4 Combination filter active carbon catalyst 5 Air purifier body 6 UV Lamp 5 4 3 2 1 Smart Auto button On Off button Settings button Se...

Page 6: ...utton The air filter starts its operation and the display turns on 1 Open the front filter flap cover 2 First remove the transparent protective foil from the filters Then insert the combi filter first...

Page 7: ...ty display shown above you will also see a PM value in the display You can read at the top which air quality category the respective PM value falls into Note The air sensor is located at the front rig...

Page 8: ...verwritten and saved 7 Setting the fan strength air circulation Press the Fan Speed button in succession for the desired setting The device has three fan speeds Level 1 Weak fan strength air circulati...

Page 9: ...tivities on your device 11 1 Cleaning Use a soft and damp cloth to clean the outside of the device Use only mild cleaning agents to clean your air purifier Please make sure that water does not get ins...

Page 10: ...utomatic air sensor and in case of 9 x active light bars poor air quality the instructions listed below If the explanations given there are not applicable and the air sensor clearly indicates a wrong...

Page 11: ...the odors again Others Declaration of warranty Notwithstanding the statutory warranty claims the manufacturer grants a warranty in accordance with the laws of your country but at least 1 year in Germ...

Page 12: ...contain valuable recyclable materials that should be recycled In addition the environment or human health should not be polluted by uncontrolled waste disposal Therefore please dispose of old devices...

Reviews: