Aktobis WDH-C03 User Manual Download Page 3

 

Aktobis AG,  Borsigstr. 20,  D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: [email protected] 

 
 
 

Important safety instructions: 

 

 

Operate the unit only in a straight position and with a straight/level stand ! 

 

Ensure a minimum lateral distance of 30 cm and a minimum upper distance of 30 cm to inventory and 
walls!  

 

Do not place any objects on top of the unit and make sure that the air intake as well as the exhaust air are 
always free ! 

 

The appliance is not a substitute for room ventilation and is not suitable as an extractor hood when 
cooking. 

 

Ventilate the room regularly. Especially if it is a very airtight room or if there is a high oxygen consumption 
(e.g. fireplace, gas stove, many people, etc.). 

 

Supervise the air purifier if there are children or animals near the device ! 

 

This air purifier should only be operated by persons who have the necessary physical as well as mental 
abilities to operate this device without problems/flawlessly ! 

 

Pay attention to the electricity, never go into the device with objects or put them in ! 

 

Only qualified personnel or electricians are allowed to open the unit or to make repairs on the unit and/or 
the power cord (power plug) ! 

 

Protect the device from all moisture and wetness ! 

 

Use only the recommended voltage for the operation of the device ! 

 

Make sure that the power cord is unfolded (untied) before connecting it to the power  

 

Make sure that the plug is clean and properly connected to the power outlet before operating the unit ! 

 

Do not expose the filters to insect spray, they could later release/release the insect spray unintentionally ! 

 

Avoid that ash (cigarette ash) is sucked in by the device, this can lead to fire in the worst case ! 

 

Switch off the device before unplugging the power cord ! 

 

Switch off the device and disconnect the power plug if you want to clean the device ! 

 

Clean the device only with mild cleaning agents ! 

 

Avoid using the device at high room temperatures or in humid conditions ! 

 

Do not make any independent modifications to the device or the cables ! 

 

Never touch the plug or the socket with wet hands ! 

 

Make sure that flammable substances (e.g. gases/oils etc.) are never in the vicinity of the device ! 

 

If you are not going to use the device for a longer period of time, switch it off and disconnect the power 
plug! 

 

Never look directly into the switched on UV light, it can cause injuries to the eye ! 

 
 

Please switch off the device immediately and remove it from the power/mains if something seems to be 
wrong !!! In this case, please contact a specialist and do not try to repair the device yourself !! 

 
Examples:

 Fuse has blown or the unit is making unusual noises and/or there is a burnt smell. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for WDH-C03

Page 1: ...ps In case of any problems We hope the device meets your expectations If despite the greatest possible care there should ever be cause for complaint we ask you to contact us briefly because we are ver...

Page 2: ...articles in the room Airquality sensor optionally switchable Automatically measures the air quality If the determined air quality is good the air purifier automatically turns OFF If the result is oppo...

Page 3: ...he recommended voltage for the operation of the device Make sure that the power cord is unfolded untied before connecting it to the power Make sure that the plug is clean and properly connected to the...

Page 4: ...ntrol receiver 6 Filter change indicator 2 Signal lamp anion function 7 Operating keys air sensor air circulation 3 Signal lamp UV light function Timer Operating Mode Reset 4 Display of the current te...

Page 5: ...ilter compartment diagram 1 Filter flap 2 Prefilter 3 HEPA Filter 4 Combination filter active carbon catalyst 5 Air purifier body 6 UV Lamp 5 4 3 2 1 Smart Auto button On Off button Settings button Se...

Page 6: ...utton The air filter starts its operation and the display turns on 1 Open the front filter flap cover 2 First remove the transparent protective foil from the filters Then insert the combi filter first...

Page 7: ...ty display shown above you will also see a PM value in the display You can read at the top which air quality category the respective PM value falls into Note The air sensor is located at the front rig...

Page 8: ...verwritten and saved 7 Setting the fan strength air circulation Press the Fan Speed button in succession for the desired setting The device has three fan speeds Level 1 Weak fan strength air circulati...

Page 9: ...tivities on your device 11 1 Cleaning Use a soft and damp cloth to clean the outside of the device Use only mild cleaning agents to clean your air purifier Please make sure that water does not get ins...

Page 10: ...utomatic air sensor and in case of 9 x active light bars poor air quality the instructions listed below If the explanations given there are not applicable and the air sensor clearly indicates a wrong...

Page 11: ...the odors again Others Declaration of warranty Notwithstanding the statutory warranty claims the manufacturer grants a warranty in accordance with the laws of your country but at least 1 year in Germ...

Page 12: ...contain valuable recyclable materials that should be recycled In addition the environment or human health should not be polluted by uncontrolled waste disposal Therefore please dispose of old devices...

Reviews: