background image

 

Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany 

www.AKTOBIS.de

 

Email: [email protected] 

 
 
 
 

Please switch off the unit immediately and disconnect it from the mains/power supply if anything 
seems to be wrong !!! In this case, please contact a specialist and do not attempt to repair the 
unit yourself !!! 

 

Examples:

 Fan does not run during operation, fuse has blown or compressor rattles loudly. 

 
 

Important operating and safety instructions regarding the refrigerant R290 in this unit: 

 

 

Read these instructions carefully and observe them strictly ! 

 

The unit operates with the refrigerant R290. This refrigerant is highly flammable and explosive if the safety 
instructions are not observed! 

 

The unit should not be stored or operated in a room with burning/heating appliances or open fire ! 

 

Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately by an 
emerging odour ! 

 

Make sure that the outlet of the exhaust air is always ensured and not obstructed by other objects ! 

 

Ensure a minimum distance of at least 50 cm from open flames and heating elements ! 

 

Set-up, operation and storage of the unit should take place in a room with a minimum size of 4 

m2 !

 

 

When cleaning, proceed strictly according to the manufacturer's instructions and do not use any additional heat 
sources to possibly accelerate the defrosting process of the appliance ! 

 
 
 

This unit has parts that must not be replaced or repaired ! 

 

The refrigerant cannot be renewed or replaced ! 

 

Do not carry out any independent repairs or modifications to your unit ! 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for WDH-520EB

Page 1: ...ccur despite careful instructions on the carton For this reason we ask you to leave the unit upright for at least 4 hours before using it for the first time 4 hours before using the unit for the first...

Page 2: ...Do not place any objects on the dehumidifier Do not block the exhaust air fins of the unit and please ensure sufficient space clearance at and around the fan Ensure that there is sufficient air suppl...

Page 3: ...rved The unit should not be stored or operated in a room with burning heating appliances or open fire Please note that the refrigerant is odourless and therefore a leak cannot be detected immediately...

Page 4: ...Aktobis AG Borsigstr 20 D 63110 Rodgau Germany www AKTOBIS de Email info aktobis de Description of the unit parts Functional description...

Page 5: ...he TIMER key Determining the remaining running time Press the TIMER button during operation to select the desired remaining running time of the dehumidifier A value between 1 12 hours can be selected...

Page 6: ...ing or uneven ground 4 4 Please always keep a distance of approx 20 cm to the wall to avoid possible overheating of the appliance Furthermore please also ensure a distance of approx 50 cm upwards when...

Page 7: ...ty air filter Fold the carrying handle upwards and then remove the air filter upwards from its holder It is best to clean the air filter carefully under lukewarm water or with a low setting suction po...

Page 8: ...at the unit inlet and of course these values only apply if the temperature and moisture content remain constant The unit rattles or makes running noises Running noises are usually caused by the air f...

Page 9: ...s Completely or partially dismantled units Conformity The dehumidifier has been tested and itself and or parts thereof have been manufactured under the following safety standards T V Rheinland GS test...

Reviews: